RELAX ‐Jr: An Automated Pre‐Processing Pipeline for Developmental EEG Recordings
Human Brain Mapping · 2024
DOI: 10.1002/hbm.70034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, 2024. Verfasst von Aron T Hill und 3 weiteren Autor:innen. Beteiligte Einrichtung: Cognitive Neuroscience Unit, School of Psychology, Deakin University, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Electroencephalography, Artifacts, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Australian Research Council, National Health and Medical Research Council of Australia.
Abstract (Originalsprache)
Automated EEG pre‐processing pipelines provide several key advantages over traditional manual data cleaning approaches; primarily, they are less time‐intensive and remove potential experimenter error/bias. Automated pipelines also require fewer technical expertise as they remove the need for manual artefact identification. We recently developed the fully automated Reduction of Electroencephalographic Artefacts (RELAX) pipeline and demonstrated its performance in cleaning EEG data recorded from adult populations. Here, we introduce the RELAX‐Jr pipeline, which was adapted from RELAX and designed specifically for pre‐processing of data collected from children. RELAX‐Jr implements multi‐channel Wiener filtering (MWF) and/or wavelet‐enhanced independent component analysis (wICA) combined with the adjusted‐ADJUST automated independent component classification algorithm to identify and reduce all artefacts using algorithms adapted to optimally identify artefacts in EEG recordings taken from children. Using a dataset of resting‐state EEG recordings ( N = 136) from children spanning early‐to‐middle childhood (4–12 years), we assessed the cleaning performance of RELAX‐Jr using a range of metrics including signal‐to‐error ratio, artefact‐to‐residue ratio, ability to reduce blink and muscle contamination, and differences in estimates of alpha power between eyes‐open and eyes‐closed recordings. We also compared the performance of RELAX‐Jr against four publicly available automated cleaning pipelines. We demonstrate that RELAX‐Jr provides strong cleaning performance across a range of metrics, supporting its use as an effective and fully automated cleaning pipeline for neurodevelopmental EEG data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cognitive Neuroscience Unit, School of Psychology, Deakin University, Melbourne, Victoria, Australia.
- Monarch Research Institute, Monarch Mental Health Group, Sydney, New South Wales, Australia.
- School of Medicine and Psychology, The Australian National University, Canberra, Australian Capital Territory, Australia.
Förderung
- Australian Research Council
- National Health and Medical Research Council of Australia
Zitieren
APA
Hill, A. T., Enticott, P. G., Fitzgerald, P. B., & Bailey, N. W. (2024). RELAX ‐Jr: An Automated Pre‐Processing Pipeline for Developmental EEG Recordings. Human Brain Mapping. https://doi.org/10.1002/hbm.70034
Vancouver
Hill AT, Enticott PG, Fitzgerald PB, Bailey NW. RELAX ‐Jr: An Automated Pre‐Processing Pipeline for Developmental EEG Recordings. Human Brain Mapping. 2024. doi:10.1002/hbm.70034
BibTeX
@article{Hill2024,
author = {Hill, Aron T and Enticott, Peter G and Fitzgerald, Paul B and Bailey, Neil W},
title = {RELAX ‐Jr: An Automated Pre‐Processing Pipeline for Developmental EEG Recordings},
journal = {Human Brain Mapping},
year = {2024},
doi = {10.1002/hbm.70034}
}
EUVIMED