Integrated diffusion image operator ( iDIO ): A pipeline for automated configuration and processing of diffusion MRI data
Human Brain Mapping · 2023
DOI: 10.1002/hbm.26239 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, 2023. Verfasst von Chih-Chin Heather Hsu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Neuroscience, National Yang Ming Chiao Tung University, Taipei, Taiwan. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, National Institutes of Health, U.S. Department of Defense.
Abstract (Originalsprache)
The preprocessing of diffusion magnetic resonance imaging (dMRI) data involve numerous steps, including the corrections for head motion, susceptibility distortion, low signal‐to‐noise ratio, and signal drifting. Researchers or clinical practitioners often need to configure different preprocessing steps depending on disparate image acquisition schemes, which increases the technical threshold for dMRI analysis for nonexpert users. This could cause disparities in data processing approaches and thus hinder the comparability between studies. To make the dMRI data processing steps transparent and adapt to various dMRI acquisition schemes for researchers, we propose a semi‐automated pipeline tool for dMRI named integrated diffusion image operator or iDIO. This pipeline integrates features from a wide range of advanced dMRI software tools and targets at providing a one‐click solution for dMRI data analysis, via adaptive configuration for a set of suggested processing steps based on the image header of the input data. Additionally, the pipeline provides options for post‐processing, such as estimation of diffusion tensor metrics and whole‐brain tractography‐based connectomes reconstruction using common brain atlases. The iDIO pipeline also outputs an easy‐to‐interpret quality control report to facilitate users to assess the data quality. To keep the transparency of data processing, the execution log and all the intermediate images produced in the iDIO's workflow are accessible. The goal of iDIO is to reduce the barriers for clinical or nonspecialist users to adopt the state‐of‐art dMRI processing steps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Neuroscience, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Center for Geriatrics and Gerontology, Taipei Veterans General Hospital, Taipei, Taiwan.
- Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.
- Shanghai Key Laboratory of Brain Functional Genomics (Ministry of Education), Affiliated Mental Health Center (ECNU), School of Psychology and Cognitive Science, East China Normal University, Shanghai, China.
- Shanghai Changning Mental Health Center, Shanghai, China.
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan.
ORCID-Profile: Chih-Chin Heather Hsu, Yi-Chia Kung
Förderung
- NIH HHS
- National Institutes of Health
- U.S. Department of Defense
Zitieren
APA
Hsu, C. H., Chong, S. T., Kung, Y. C., Kuo, K. T., Huang, C. C., & Lin, C. P. (2023). Integrated diffusion image operator ( iDIO ): A pipeline for automated configuration and processing of diffusion MRI data. Human Brain Mapping. https://doi.org/10.1002/hbm.26239
Vancouver
Hsu CH, Chong ST, Kung YC, Kuo KT, Huang CC, Lin CP. Integrated diffusion image operator ( iDIO ): A pipeline for automated configuration and processing of diffusion MRI data. Human Brain Mapping. 2023. doi:10.1002/hbm.26239
BibTeX
@article{Hsu2023,
author = {Hsu, Chih-Chin Heather and Chong, Shin Tai and Kung, Yi-Chia and Kuo, Kuan-Tsen and Huang, Chu-Chung and Lin, Ching-Po},
title = {Integrated diffusion image operator ( iDIO ): A pipeline for automated configuration and processing of diffusion MRI data},
journal = {Human Brain Mapping},
year = {2023},
doi = {10.1002/hbm.26239}
}
EUVIMED