EUVIMEDEUVIMED entdecken
Crossref

Guide‐Unit Modified Conjugate Flow Field for Improved Mass Transfer in PEMFC Bipolar Plates

Zhonglan Hou, Yibo Zhang, Pengyan Guo, Perk Lin Chong, Fuwang Zhou

Fuel Cells · 2026-08 · 26 (4)

DOI: 10.1002/fuce.70150 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fuel Cells, online erschienen am 22.08.2026. Verfasst von Zhonglan Hou und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: China Scholarship Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Proton exchange membrane fuel cells (PEMFCs) operating at high power density are often constrained by non‐uniform reactant distribution, local liquid water accumulation, and concentration polarization. To address insufficient under‐rib oxygen transport, weak‐reaction regions, and unstable water removal in conventional two‐pass serpentine flow fields, this study proposes a conjugate dual‐channel serpentine flow field incorporating local guide units for metallic bipolar plates. On each bipolar plate face, the reactant stream supplied through a common inlet is divided into two parallel serpentine branches, which are arranged in an in‐plane mirror‐symmetric configuration and subsequently recombine at a common outlet. The same geometry is independently employed on the anode and cathode sides, with the two flow fields arranged mirror‐symmetrically across the membrane electrode assembly. A three‐dimensional non‐isothermal multiphysics model is developed to investigate the mass transport, electrochemical behavior, and water‐management performance of the proposed configurations. Compared with the baseline two‐pass serpentine flow field, the designs incorporating guide units increase the oxygen uniformity index from 0.689 to 0.773–0.776, reduce the current‐density non‐uniformity index from 0.133 to 0.092–0.095, and increase the minimum current flux density in weak‐reaction regions to 6.27–9.95 times the baseline value. The wing‐shaped configuration provides the best overall balance among oxygen uniformity, current‐density uniformity, pressure‐drop penalty, and liquid water control. The U‐shaped configuration shows a greater tendency toward water retention, whereas the trapezoidal and Tesla‐valve‐shaped configurations incur larger pressure‐drop penalties. The results demonstrate that the local guide units improve active‐area utilization primarily by inducing transverse reactant transport, enhancing under‐rib oxygen supply, and mitigating weak‐reaction regions rather than merely increasing the local peak current density. The proposed structure combines enhanced mass transfer and improved water management with potential compatibility with single‐step stamping, providing a reference for metallic bipolar plate flow‐field design in high‐power‐density PEMFCs.

Förderung

  • China Scholarship Council

Zitieren

APA

Hou, Z., Zhang, Y., Guo, P., Chong, P. L., & Zhou, F. (2026). Guide‐Unit Modified Conjugate Flow Field for Improved Mass Transfer in PEMFC Bipolar Plates. Fuel Cells, 26(4). https://doi.org/10.1002/fuce.70150

Vancouver

Hou Z, Zhang Y, Guo P, Chong PL, Zhou F. Guide‐Unit Modified Conjugate Flow Field for Improved Mass Transfer in PEMFC Bipolar Plates. Fuel Cells. 2026;26(4). doi:10.1002/fuce.70150

BibTeX
@article{Hou2026,
  author = {Hou, Zhonglan and Zhang, Yibo and Guo, Pengyan and Chong, Perk Lin and Zhou, Fuwang},
  title = {Guide‐Unit Modified Conjugate Flow Field for Improved Mass Transfer in PEMFC Bipolar Plates},
  journal = {Fuel Cells},
  year = {2026},
  volume = {26},
  number = {4},
  doi = {10.1002/fuce.70150}
}
Kostenlos starten →