EUVIMEDDescubrir EUVIMED
Open access · CC BY-NC-ND 4.0

A Dual‐Mode Triple‐Signal Flexible Pressure Sensor Based on Laser‐Induced Graphene

Jianing Zhang, Deng Wang, Peilong Li, Zhe Liu, Ruyu Zhang, Bowen Lu, Feng Liu

FlexTech · 2026-11-19

DOI: 10.1002/fle2.70028 ↗

At a glance

Journal article in FlexTech, published online on 2026-11-19. Written by Jianing Zhang and 6 co-authors. 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: National Natural Science Foundation of China.

ResumenDatos bibliográficosCiteRelated studies

Abstract (original language)

Mechanical reliability is crucial for the application of flexible sensors that are frequently subjected to bending. Herein, to improve the mechanical reliability of flexible pressure sensors, a strategy based on signal redundancy and the complementary integration of piezocapacitive and piezoresistive sensing modes was used to implement a dual‐mode triple‐signal flexible pressure sensor. The sensor consists of a pair of interdigital electrodes, an Ecoflex elastomer loaded with a laser‐induced graphene (LIG) layer, and a bottom electrode. Under external pressure, the resistive channel formed by the interdigital electrodes and LIG layer generates a piezoresistive signal, whereas two capacitive channels formed by the interdigital electrodes, elastomer, and bottom electrode generate two piezocapacitive signals. Therefore, the sensor has two redundant signals, which obviously improves its mechanical reliability. Moreover, the sensor can operate in both piezocapacitive and piezoresistive modes simultaneously, which is beneficial for improving its overall performance through mode complementarity. In the piezocapacitive mode, the sensor exhibits sensitivities of 0.1602 kPa −1 and 0.1548 kPa −1 with response/recovery times of 92/128 ms and 76/114 ms, respectively. In the piezoresistive mode, the sensor has a high sensitivity of 38.64 kPa −1 with a response/recovery time of 100/83 ms. Furthermore, the sensor maintained reliable signal outputs after more than 4000 loading cycles, demonstrating excellent durability. The application in human motion monitoring shows that the sensor can effectively detect physiological signals while maintaining a consistent response of the three output channels. This work provides a new strategy for improving the mechanical reliability of flexible pressure sensors through multisignal redundancy design and mode complementarity.

Funding

  • National Natural Science Foundation of China

Cite

APA

Zhang, J., Wang, D., Li, P., Liu, Z., Zhang, R., Lu, B., & Liu, F. (2026). A Dual‐Mode Triple‐Signal Flexible Pressure Sensor Based on Laser‐Induced Graphene. FlexTech. https://doi.org/10.1002/fle2.70028

Vancouver

Zhang J, Wang D, Li P, Liu Z, Zhang R, Lu B, et al. A Dual‐Mode Triple‐Signal Flexible Pressure Sensor Based on Laser‐Induced Graphene. FlexTech. 2026. doi:10.1002/fle2.70028

BibTeX
@article{Zhang2026,
  author = {Zhang, Jianing and Wang, Deng and Li, Peilong and Liu, Zhe and Zhang, Ruyu and Lu, Bowen and Liu, Feng},
  title = {A Dual‐Mode Triple‐Signal Flexible Pressure Sensor Based on Laser‐Induced Graphene},
  journal = {FlexTech},
  year = {2026},
  doi = {10.1002/fle2.70028}
}
Start for free →