Composition‐Sensitive Optimization of Mixed Refrigerant Blends for Hydrogen Liquefaction and Storage Using Prediction Based Clustering Method

Md Shaquib Equbal, Osama Khan, Praveen Pachauri, Mohd Parvez, Taufique Ahamad, Brahmdeo Yadav, Haidar Howari, Ashok Kumar Yadav, Anoop Kumar Shukla

Energy Storage · 2026-12 · 8 (8)

DOI: 10.1002/est2.70552 ↗

At a glance

Journal article in Energy Storage, published online on 2026-10-29. Written by Md Shaquib Equbal and 8 co-authors. 34 references.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The growing hydrogen demands have instigated massive developments in the hydrogen liquefaction technology. Hydrogen fuel is potentially seen as a critical aspect toward developing economies and requires substantial improvement in liquefaction mechanisms. The current study explores the hydrogen liquefaction‐storage through mixed refrigerants with the goal of increasing overall efficiency of the process. A hybrid method is applied which makes use of Pearson correlation, prediction modeling, and k‐means clustering to optimize the process operational parameters. The optimization process showed that an optimal mixed refrigerant composition, MR‐6 (Combo 6), which provides an energy consumption of 7.6 kWh/kg, hydrogen storage of 93.2%, and a COP of 3.9. The given composition had strong positive correlations to C3 ( R = 0.884) and n‐C5 ( R = 0.866) with COP. However, a high negative correlation is established with the COP with N 2 ( R = −0.888) and Ne ( R = −0.874). The cluster 2 gave the best performance results, especially for Combination 6. Further, the ANFIS model has shown that the Gaussian function membership function yielded the best predictions (RMSE 0.15, MAE 0.05), whereas the Trapezoidal function has produced the greatest errors (RMSE 0.25, MAE 0.09) for the liquefaction‐based outcomes. The optimum composition is found to be MR‐6 with the composition C1(10%), C2(0%), C2*(10%), C3(5%), n‐C4(5%), i‐C5(5%), n‐C5(5%), R14(10%), He (10%), Ne (10%), N 2 (5%), R23(15%).

Cite

APA

Equbal, M. S., Khan, O., Pachauri, P., Parvez, M., Ahamad, T., Yadav, B., Howari, H., Yadav, A. K., & Shukla, A. K. (2026). Composition‐Sensitive Optimization of Mixed Refrigerant Blends for Hydrogen Liquefaction and Storage Using Prediction Based Clustering Method. Energy Storage, 8(8). https://doi.org/10.1002/est2.70552

Vancouver

Equbal MS, Khan O, Pachauri P, Parvez M, Ahamad T, Yadav B, et al. Composition‐Sensitive Optimization of Mixed Refrigerant Blends for Hydrogen Liquefaction and Storage Using Prediction Based Clustering Method. Energy Storage. 2026;8(8). doi:10.1002/est2.70552

BibTeX
@article{Equbal2026,
  author = {Equbal, Md Shaquib and Khan, Osama and Pachauri, Praveen and Parvez, Mohd and Ahamad, Taufique and Yadav, Brahmdeo and Howari, Haidar and Yadav, Ashok Kumar and Shukla, Anoop Kumar},
  title = {Composition‐Sensitive Optimization of Mixed Refrigerant Blends for Hydrogen Liquefaction and Storage Using Prediction Based Clustering Method},
  journal = {Energy Storage},
  year = {2026},
  volume = {8},
  number = {8},
  doi = {10.1002/est2.70552}
}
Start for free →