EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Seismic Isolation Retrofit Following Early Design Standards: A Case Study

Ricardo Bustamante, Gilberto Mosqueda, Kayla Erler, Claudio Sepulveda, Maikol Del Carpio, Joshua Lopez, Kenneth J. Elwood

Earthquake Spectra · 2027-02 · 43 (1)

DOI: 10.1002/esp4.70141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Earthquake Spectra, online erschienen am 23.11.2026. Verfasst von Ricardo Bustamante und 6 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: University of California, San Diego.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Seismic isolation has been widely applied especially for the design of new essential structures and for retrofit of historical buildings in high seismic risk regions. For new designs, the isolated superstructure is designed to remain essentially elastic for the considered seismic hazard, providing limited damage compared to conventional fixed‐based structures. Similarly, retrofit applications aim to limit superstructure base shear below the yield capacity. Notably, design standards for seismic isolation have evolved toward stricter requirements in recent years. To examine early retrofit applications, a seismic performance assessment is conducted on a historical building retrofitted with base isolation in the early 1990s. The structure is examined using current seismic evaluation and design requirements for seismically isolated structures and found to require further assessment. Modifications limited to the isolation system are explored by examining the feasible domain of the isolation system properties that provide adequate performance, while considering the nonlinear superstructure response, moat wall pounding, and variability in isolation system behavior through property modification factors. Improved performance is achieved by increasing the effective isolation period to reduce demands on the superstructure combined with supplemental damping to maintain reasonable isolation system displacements. Supplemental viscous damping below 15% of critical and the use of nonlinear viscous dampers with a velocity exponent α ≥ 0.7 are found to be most effective. The framework presented in this study provides a useful tool for evaluation of retrofit design alternatives considering simplified nonlinear models and considering a balance between the superstructure base shear capacity and the isolation system displacement capacity.

Förderung

  • University of California, San Diego

Zitieren

APA

Bustamante, R., Mosqueda, G., Erler, K., Sepulveda, C., Carpio, M. D., Lopez, J., & Elwood, K. J. (2027). Seismic Isolation Retrofit Following Early Design Standards: A Case Study. Earthquake Spectra, 43(1). https://doi.org/10.1002/esp4.70141

Vancouver

Bustamante R, Mosqueda G, Erler K, Sepulveda C, Carpio MD, Lopez J, et al. Seismic Isolation Retrofit Following Early Design Standards: A Case Study. Earthquake Spectra. 2027;43(1). doi:10.1002/esp4.70141

BibTeX
@article{Bustamante2027,
  author = {Bustamante, Ricardo and Mosqueda, Gilberto and Erler, Kayla and Sepulveda, Claudio and Carpio, Maikol Del and Lopez, Joshua and Elwood, Kenneth J.},
  title = {Seismic Isolation Retrofit Following Early Design Standards: A Case Study},
  journal = {Earthquake Spectra},
  year = {2027},
  volume = {43},
  number = {1},
  doi = {10.1002/esp4.70141}
}
Kostenlos starten →