EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

System‐Level Design and Technoeconomic Analysis of a Hybrid Backup‐Power System for Enhancing Grid Reliability: A Case Study of Haramaya University, Ethiopia

Wondwosen S. Aga, Ayele N. Legesse, Belete Tefera, Biruk S. Gebremichael

Energy Science & Engineering · 18.11.2026

DOI: 10.1002/ese3.70680 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Science & Engineering, online erschienen am 18.11.2026. Verfasst von Wondwosen S. Aga und 3 weiteren Autor:innen. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reliable and sustainable energy access is essential for improving livelihoods and supporting economic development. However, continued reliance on fossil fuels poses significant environmental and climate challenges, underscoring the urgent need for cleaner, decentralized energy solutions. Hybrid renewable‐energy systems offer a viable pathway to enhance grid reliability while reducing dependence on diesel‐based backup generation. This study aims to design and assess the technoeconomic feasibility of a grid‐connected hybrid energy system operating as backup power during grid outages at the Haramaya Institute of Technology (HiT) campus. Site‐specific data, including solar‐resource availability, campus electricity load profiles, and system component specifications and sizing, were collected and analyzed. Multiple hybrid backup‐power configurations were then modeled and optimized using HOMER@Grid based on key technoeconomic indicators, including net present cost, levelized cost of energy (LCOE), payback period, internal rate of return (IRR), and return on equity (ROE). The study results demonstrate that a photovoltaic–battery–grid hybrid system is the most economically optimal configuration. The optimal system achieved an LCOE of 0.165 USD/kWh, a simple payback period of 5.3 years, an IRR of 18%, and an ROE of 14%. In addition, the annual operating cost of the optimal hybrid system was estimated at USD 38,050, compared with USD 106,650 for the existing diesel‐based backup system, excluding generator maintenance costs. This represents a substantial reduction in operational expenditure while improving supply reliability. Furthermore, the successful installation of a pilot‐scale hybrid system confirms its practical feasibility and effectiveness in supporting grid reliability. Overall, the findings indicate that grid‐connected hybrid energy systems offer a reliable, cost‐effective alternative to conventional diesel generators for institutional backup‐power applications.

Zitieren

APA

Aga, W. S., Legesse, A. N., Tefera, B., & Gebremichael, B. S. (2026). System‐Level Design and Technoeconomic Analysis of a Hybrid Backup‐Power System for Enhancing Grid Reliability: A Case Study of Haramaya University, Ethiopia. Energy Science & Engineering. https://doi.org/10.1002/ese3.70680

Vancouver

Aga WS, Legesse AN, Tefera B, Gebremichael BS. System‐Level Design and Technoeconomic Analysis of a Hybrid Backup‐Power System for Enhancing Grid Reliability: A Case Study of Haramaya University, Ethiopia. Energy Science & Engineering. 2026. doi:10.1002/ese3.70680

BibTeX
@article{Aga2026,
  author = {Aga, Wondwosen S. and Legesse, Ayele N. and Tefera, Belete and Gebremichael, Biruk S.},
  title = {System‐Level Design and Technoeconomic Analysis of a Hybrid Backup‐Power System for Enhancing Grid Reliability: A Case Study of Haramaya University, Ethiopia},
  journal = {Energy Science & Engineering},
  year = {2026},
  doi = {10.1002/ese3.70680}
}
Kostenlos starten →