EUVIMEDSkopri EUVIMED
Open access · CC BY-NC 4.0

Detection of seizures with ictal tachycardia, using heart rate variability and patient adaptive logistic regression machine learning methods: A hospital‐based validation study

Jesper Jeppesen iD, Katia Lin, Hiago Murilo Melo iD, Jonatas Pavei, Jefferson Luiz Brum Marques iD, Sándor Beniczky, Roger Walz

Epileptic Disorders · 2024-04 · 26 (2) · 199-208

DOI: 10.1002/epd2.20196 ↗

At a glance

Journal article in Epileptic Disorders, published online on 2024-02-09. Written by Jesper Jeppesen and 6 co-authors. Institution: Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark. Major MEDLINE topics: Seizures, Epilepsies, Partial. Cited 12 times so far (Crossref); 28 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Danmarks Frie Forskningsfond, The Danish Agency for Higher Education and Science (The International Network Programme).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Objective

Automated seizure detection of focal epileptic seizures is needed for objective seizure quantification to optimize the treatment of patients with epilepsy. Heart rate variability (HRV)‐based seizure detection using patient‐adaptive threshold with logistic regression machine learning (LRML) methods has presented promising performance in a study with a Danish patient cohort. The objective of this study was to assess the generalizability of the novel LRML seizure detection algorithm by validating it in a dataset recorded from long‐term video‐EEG monitoring (LTM) in a Brazilian patient cohort.

Methods

Ictal and inter‐ictal ECG‐data epochs recorded during LTM were analyzed retrospectively. Thirty‐four patients had 107 seizures (79 focal, 28 generalized tonic–clonic [GTC] including focal‐to‐bilateral‐tonic–clonic seizures) eligible for analysis, with a total of 185.5 h recording. Because HRV‐based seizure detection is only suitable in patients with marked ictal autonomic change, patients with >50 beats/min change in heart rate during seizures were selected as responders. The patient‐adaptive LRML seizure detection algorithm was applied to all elected ECG data, and results were computed separately for responders and non‐responders.

Results

The patient‐adaptive LRML seizure detection algorithm yielded a sensitivity of 84.8% (95% CI: 75.6–93.9) with a false alarm rate of .25/24 h in the responder group (22 patients, 59 seizures). Twenty‐five of the 26 GTC seizures were detected (96.2%), and 25 of the 33 focal seizures without bilateral convulsions were detected (75.8%). Significance The study confirms in a new, independent external dataset the good performance of seizure detection from a previous study and suggests that the method is generalizable. This method seems useful for detecting both generalized and focal epileptic seizures. The algorithm can be embedded in a wearable seizure detection system to alert patients and caregivers of seizures and generate objective seizure counts helping to optimize the treatment of the patients.

Subjects

MeSH terms (MEDLINE)

SeizuresEpilepsies, PartialHumansHeart RateLogistic ModelsRetrospective StudiesTachycardiaMachine LearningElectroencephalography

Author keywords

electrocardiographyepilepsyfocal seizuresseizure alarm

Authors and institutions

  • Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark.
  • Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Medical Sciences Post-graduate Program, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.
  • Neurology Division, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.
  • Center for Applied Neurosciences (CeNAp), Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.
  • Graduate Program in Neuroscience, UFSC, Florianópolis, SC, Brazil.

ORCID profiles: Jesper Jeppesen, Hiago Murilo Melo, Jefferson Luiz Brum Marques

Funding

  • Danmarks Frie Forskningsfond
  • The Danish Agency for Higher Education and Science (The International Network Programme)

Cite

APA

Jeppesen, J., Lin, K., Melo, H. M., Pavei, J., Marques, J. L. B., Beniczky, S., & Walz, R. (2024). Detection of seizures with ictal tachycardia, using heart rate variability and patient adaptive logistic regression machine learning methods: A hospital‐based validation study. Epileptic Disorders, 26(2), 199-208. https://doi.org/10.1002/epd2.20196

Vancouver

Jeppesen J, Lin K, Melo HM, Pavei J, Marques JLB, Beniczky S, et al. Detection of seizures with ictal tachycardia, using heart rate variability and patient adaptive logistic regression machine learning methods: A hospital‐based validation study. Epileptic Disorders. 2024;26(2):199-208. doi:10.1002/epd2.20196

BibTeX
@article{Jeppesen2024,
  author = {Jeppesen, Jesper and Lin, Katia and Melo, Hiago Murilo and Pavei, Jonatas and Marques, Jefferson Luiz Brum and Beniczky, Sándor and Walz, Roger},
  title = {Detection of seizures with ictal tachycardia, using heart rate variability and patient adaptive logistic regression machine learning methods: A hospital‐based validation study},
  journal = {Epileptic Disorders},
  year = {2024},
  volume = {26},
  number = {2},
  pages = {199--208},
  doi = {10.1002/epd2.20196}
}
Start for free →