Journal article in Engineering Reports, published online on 2026-05-21. Written by Changhui Li and 2 co-authors. 26 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Oral inhalation therapy has been widely adopted for treating patients with respiratory diseases. Among different inhalation devices, nebulizers are widely used to transform liquid drug formulations into micrometer‐scale droplets. However, the structure–performance relationships of portable pneumatic nebulizers remain insufficiently defined, especially with respect to how local geometric features influence aerosolization characteristics. In this study, nebulizers with different nozzle apertures, gap distances, and outlet lengths were comparatively evaluated to examine the effects of key structural parameters on aerosolization performance. The FPD and MMAD of emitted droplets were sensitive to structural variation, particularly to the gap distance between the nozzle and baffle. Within the tested design space, increasing the outlet length was generally beneficial for improving aerosolization rate and reducing residual liquid in the nebulizer cup. Considering multiple performance indicators together, the 0.4–0.7–5 mm configuration (aperture–gap–outlet) showed a favorable overall balance of FPF, aerosolization rate, and low residual volume among the tested cases. Overall, these findings clarify the structure–performance relationships of the proposed portable pneumatic nebulizer and identify a promising design candidate for further refinement, rather than a fully optimized final geometry.

Funding

  • National Natural Science Foundation of China

Cite

APA

Li, C., Shi, J., & Tong, Z. (2026). Development of Novel Nebulizers: Effects of Key Device Design Parameters on Aerosolization Performance. Engineering Reports, 8(5). https://doi.org/10.1002/eng2.70833

Vancouver

Li C, Shi J, Tong Z. Development of Novel Nebulizers: Effects of Key Device Design Parameters on Aerosolization Performance. Engineering Reports. 2026;8(5). doi:10.1002/eng2.70833

BibTeX
@article{Li2026,
  author = {Li, Changhui and Shi, Jingyu and Tong, Zhenbo},
  title = {Development of Novel Nebulizers: Effects of Key Device Design Parameters on Aerosolization Performance},
  journal = {Engineering Reports},
  year = {2026},
  volume = {8},
  number = {5},
  doi = {10.1002/eng2.70833}
}
Start for free →