EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Facile and Rapid Fabrication of a Glutamate Sensor via Electropolymerization of o‐Aminophenol

Kyoko Sugiyama, Fumiya Sato, Yuto Kunitastu, Kota Honda, Yusuke Hirabayashi, Yasufumi Takahashi, Katsuhiko Sato

Electrochemical Science Advances · 2026-04 · 6 (2)

DOI: 10.1002/elsa.70022 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electrochemical Science Advances, online erschienen am 07.04.2026. Verfasst von Kyoko Sugiyama und 6 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Human Frontier Science Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microfluidic analysis enables precise fluid manipulation and high‐time‐resolution measurements in microscale environments, and has attracted considerable attention as an analytical platform suitable for detecting spatiotemporally fluctuating biomolecules such as neurotransmitters. Glutamate is a major excitatory neurotransmitter in the central nervous system, and its real‐time quantification is essential for understanding neural function and pathological mechanisms. In this study, aiming for application to microfluidic analysis, glutamate oxidase was immobilised within an electropolymerized poly(o‐aminophenol) film, allowing facile and highly reproducible fabrication of enzyme‐modified electrodes. When the response characteristics were evaluated using platinum electrodes of 3 mm and 25 µm in diameter, the microelectrode exhibited a high current density derived from radial diffusion and yielded a steady‐state response. The limit of detection and limit of quantification obtained using the 3 mm electrode were 3.22 and 10.7 µM, respectively. Furthermore, the fabricated electrode showed no measurable response toward coexisting substances such as glutamine, aspartic acid, GABA, and glucose, indicating high substrate specificity, and the maximum response was obtained at pH 7.4. These results demonstrate that enzyme immobilisation via electropolymerization is a practical method suitable for integration with microelectrodes and microfluidic devices, and is expected to contribute to in situ glutamate monitoring as well as future applications in clinical diagnostic systems.

Förderung

  • Human Frontier Science Program

Zitieren

APA

Sugiyama, K., Sato, F., Kunitastu, Y., Honda, K., Hirabayashi, Y., Takahashi, Y., & Sato, K. (2026). Facile and Rapid Fabrication of a Glutamate Sensor via Electropolymerization of o‐Aminophenol. Electrochemical Science Advances, 6(2). https://doi.org/10.1002/elsa.70022

Vancouver

Sugiyama K, Sato F, Kunitastu Y, Honda K, Hirabayashi Y, Takahashi Y, et al. Facile and Rapid Fabrication of a Glutamate Sensor via Electropolymerization of o‐Aminophenol. Electrochemical Science Advances. 2026;6(2). doi:10.1002/elsa.70022

BibTeX
@article{Sugiyama2026,
  author = {Sugiyama, Kyoko and Sato, Fumiya and Kunitastu, Yuto and Honda, Kota and Hirabayashi, Yusuke and Takahashi, Yasufumi and Sato, Katsuhiko},
  title = {Facile and Rapid Fabrication of a Glutamate Sensor via Electropolymerization of o‐Aminophenol},
  journal = {Electrochemical Science Advances},
  year = {2026},
  volume = {6},
  number = {2},
  doi = {10.1002/elsa.70022}
}
Kostenlos starten →