EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer

Klaus Welters iD, Christian Thoben iD, Christian-Robert Raddatz iD, Florian Schlottmann iD, Stefan Zimmermann iD, Detlev Belder iD

ELECTROPHORESIS · 2025

DOI: 10.1002/elps.8147 ↗

At a glance

Journal article in ELECTROPHORESIS, 2025. Written by Klaus Welters and 5 co-authors. Institution: Institute of Analytical Chemistry, Leipzig University, Leipzig, Germany. Major MEDLINE topics: Ion Mobility Spectrometry. Cited 2 times so far (Crossref); 51 references. The full text is freely available (open access, CC BY 4.0). Funded by: Deutsche Forschungsgemeinschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

We present the coupling of capillary electrophoresis to a custom‐built high‐resolution ion mobility spectrometer (IMS). This system integrates a shifted inlet potential IMS configuration with a customised nanoflow ESI sheath interface. It enables the rapid analysis of quaternary ammonium compounds (QACs) and their impurities in real‐world samples. It allowed the detection of six non‐chromophoric compounds in about 3 min. The assignment of the IMS signals to compounds was supported by matching experimentally determined collision cross‐section (CCS) values with predicted values. The system achieved a detection limit in the single‐digit picogram range with IMS resolutions of over 80.

Subjects

MeSH terms (MEDLINE)

Ion Mobility SpectrometryElectrophoresis, CapillaryQuaternary Ammonium CompoundsLimit of DetectionEquipment Design

Author keywords

collision cross sectionhyphenationion mobility spectrometrynanoflow electrospray

Substances

Quaternary Ammonium Compounds

Authors and institutions

  • Institute of Analytical Chemistry, Leipzig University, Leipzig, Germany.
  • Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Hannover, Germany.

ORCID profiles: Klaus Welters, Christian Thoben, Christian-Robert Raddatz, Florian Schlottmann, Stefan Zimmermann, Detlev Belder

Funding

  • Deutsche Forschungsgemeinschaft

Cite

APA

Welters, K., Thoben, C., Raddatz, C. R., Schlottmann, F., Zimmermann, S., & Belder, D. (2025). Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer. ELECTROPHORESIS. https://doi.org/10.1002/elps.8147

Vancouver

Welters K, Thoben C, Raddatz CR, Schlottmann F, Zimmermann S, Belder D. Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer. ELECTROPHORESIS. 2025. doi:10.1002/elps.8147

BibTeX
@article{Welters2025,
  author = {Welters, Klaus and Thoben, Christian and Raddatz, Christian-Robert and Schlottmann, Florian and Zimmermann, Stefan and Belder, Detlev},
  title = {Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer},
  journal = {ELECTROPHORESIS},
  year = {2025},
  doi = {10.1002/elps.8147}
}
Start for free →