Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer
ELECTROPHORESIS · 2025
DOI: 10.1002/elps.8147 ↗At a glance
Journal article in ELECTROPHORESIS, 2025. Written by Klaus Welters and 5 co-authors. Institution: Institute of Analytical Chemistry, Leipzig University, Leipzig, Germany. Major MEDLINE topics: Ion Mobility Spectrometry. Cited 2 times so far (Crossref); 51 references. The full text is freely available (open access, CC BY 4.0). Funded by: Deutsche Forschungsgemeinschaft.
Topics: Mobilisation
Abstract (original language)
We present the coupling of capillary electrophoresis to a custom‐built high‐resolution ion mobility spectrometer (IMS). This system integrates a shifted inlet potential IMS configuration with a customised nanoflow ESI sheath interface. It enables the rapid analysis of quaternary ammonium compounds (QACs) and their impurities in real‐world samples. It allowed the detection of six non‐chromophoric compounds in about 3 min. The assignment of the IMS signals to compounds was supported by matching experimentally determined collision cross‐section (CCS) values with predicted values. The system achieved a detection limit in the single‐digit picogram range with IMS resolutions of over 80.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Institute of Analytical Chemistry, Leipzig University, Leipzig, Germany.
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Hannover, Germany.
ORCID profiles: Klaus Welters, Christian Thoben, Christian-Robert Raddatz, Florian Schlottmann, Stefan Zimmermann, Detlev Belder
Funding
- Deutsche Forschungsgemeinschaft
Cite
APA
Welters, K., Thoben, C., Raddatz, C. R., Schlottmann, F., Zimmermann, S., & Belder, D. (2025). Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer. ELECTROPHORESIS. https://doi.org/10.1002/elps.8147
Vancouver
Welters K, Thoben C, Raddatz CR, Schlottmann F, Zimmermann S, Belder D. Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer. ELECTROPHORESIS. 2025. doi:10.1002/elps.8147
BibTeX
@article{Welters2025,
author = {Welters, Klaus and Thoben, Christian and Raddatz, Christian-Robert and Schlottmann, Florian and Zimmermann, Stefan and Belder, Detlev},
title = {Coupling Capillary Electrophoresis With a Shifted Inlet Potential High‐Resolution Ion Mobility Spectrometer},
journal = {ELECTROPHORESIS},
year = {2025},
doi = {10.1002/elps.8147}
}
EUVIMED