Development and Validation of the 9‐Dye Fluorescent Autosomal and Y Chromosome Multiplex STR Amplification System
ELECTROPHORESIS · 2025
DOI: 10.1002/elps.8130 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift ELECTROPHORESIS, 2025. Verfasst von Yu Hao und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Forensic Science, Ministry of Public Security, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Chromosomes, Human, Y, Multiplex Polymerase Chain Reaction, Microsatellite Repeats, Fluorescent Dyes. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: 14th Five Year National Key Research and Development Program of China..
Abstract (Originalsprache)
To develop a 9‐dye fluorescent autosomal and Y chromosome STR multiplex amplification system and verify its performance. Using the 9‐dye fluorescent labeling technology, construct a multiplex amplification system that uses the autosomal and Y chromosome core and preferred loci recommended by GB/T 41009‐2021 national standard as candidate loci, then evaluate its accuracy, sensitivity, species specificity, and other system performance index. A 9‐dye fluorescent multiplex amplification system containing 70 loci, including Amel, D5S818, D21S11, D7S820, CS1FPO, D2S1338, D19S433, D8S1132, D2S441, VWA, D8S1179, D16S539, D10S1435, PentaD, D3S3045, TPOX, TH01, D22S1045, D18S51, FGA, D19S253, D10S1248, D6S477, D6S1043, D13S317, D12S391, D15S659, PentaE, D1S1656, D3S1358, DYS460, DYS389I, DYS390, DYS533, DYS392, DYS518, DYS557, DYS570, DYS458, DYS437, DYS385, GATA‐H4, DYS576, DYS643, DYS508, DYS627, DYS456, DYS391, DYF404S1, DYS438, DYS448, DYF387S1, DYS596, DYS549, DYS399S1, DYS393, DYS635, DYS439, DYS19, DYS444, DYS449, DYS481, DYS527a/b, and DYS447 was successfully constructed. The various loci in this system are well balanced, with a sensitivity of 0.0625 ng and a certain ability to detect mixture samples. This system can obtain rich locus information through a single test and meet the needs of routine testing cases and DNA database construction. It has a good practical significance in forensic medicine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Forensic Science, Ministry of Public Security, Beijing, People's Republic of China.
- Hebei Medical University, Shijiazhuang, Hebei, People's Republic of China.
Förderung
- 14th Five Year National Key Research and Development Program of China.
Zitieren
APA
Hao, Y., Zhe, Z., Yuling, C., Chenjia, L., Xiaoting, M., Lei, S., Wen, S., Lina, J., Jing, W., Wanshui, L., & Xue, B. (2025). Development and Validation of the 9‐Dye Fluorescent Autosomal and Y Chromosome Multiplex STR Amplification System. ELECTROPHORESIS. https://doi.org/10.1002/elps.8130
Vancouver
Hao Y, Zhe Z, Yuling C, Chenjia L, Xiaoting M, Lei S, et al. Development and Validation of the 9‐Dye Fluorescent Autosomal and Y Chromosome Multiplex STR Amplification System. ELECTROPHORESIS. 2025. doi:10.1002/elps.8130
BibTeX
@article{Hao2025,
author = {Hao, Yu and Zhe, Zhang and Yuling, Cui and Chenjia, Li and Xiaoting, Mo and Lei, Shang and Wen, Song and Lina, Jia and Jing, Wang and Wanshui, Li and Xue, Bai},
title = {Development and Validation of the 9‐Dye Fluorescent Autosomal and Y Chromosome Multiplex STR Amplification System},
journal = {ELECTROPHORESIS},
year = {2025},
doi = {10.1002/elps.8130}
}