Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications
ELECTROPHORESIS · 2025
DOI: 10.1002/elps.8113 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, 2025. Verfasst von Alexandra R Hyler und 11 weiteren Autor:innen. Beteiligte Einrichtung: CytoRecovery, Inc., Blacksburg, Virginia, USA. Hauptthemen laut MEDLINE: Dimethylpolysiloxanes, Cell Separation, Microfluidic Analytical Techniques, Electrophoresis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, National Science Foundation.
Abstract (Originalsprache)
Understanding cells from complex biological samples is vital to understanding cellular biology and medical applications. One evolving tool for cell sorting is the use of microfluidic devices to achieve higher precision and remove the need for labeling cell subpopulations. However, few microfluidic devices have been translated commercially beyond academic research often due to challenges in larger scale fabrication. Here, we initially investigated a compelling label‐free microfluidic device with complex geometries to perform contactless dielectrophoresis (cDEP) for applications in enriching cell subpopulations in oncology, neurology, stem cells, and sample preparation. We began scaling the manufacturing of cDEP devices using Dow Sylgard 184, more commonly referred to as PDMS (polydimethylsiloxane). However, we began observing a new, dynamic bubble formation phenomenon which had significant impacts on device performance. Within just 5 min of exposure at typical experimental values, cell death was nearly 100%. Variables related to manufacturing, environment, equipment, personnel, raw materials sourcing, lithography methods and experimental conditions/parameters were systematically evaluated to find the root cause of the exacerbated bubble formation observed. Further, alternate polymers were sourced for manufacturing and experimental performance comparisons. All variables investigated failed to solve the significant decline in device performance and increase in cell death. Upon completing chemical analysis in this work, we conclude that the decline in device performance was a direct result of changes to the expected PDMS properties and composition. Despite these challenges, our robust quality control combined with experimental protocols to remove bubbles from the cDEP devices achieved consistent experimental performance including 2–3 h run times and >90% cell viability after sorting. These new PDMS behaviors will need to continue to be monitored and controlled to ensure consistency in experimentation, application and commercialization feasibility for a wide variety of microfluidic device designs and applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CytoRecovery, Inc., Blacksburg, Virginia, USA.
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech-Emory University, Atlanta, Georgia, USA.
- Laborie Medical Technologies Corp, Portsmouth, New Hampshire, USA.
- Phase, Inc., Charlotte, North Carolina, USA.
- Center for Biomodular Multiscale Systems for Precision Medicine, Lawrence, Kansas, USA.
- Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia, USA.
Förderung
- NIBIB NIH HHS
- NIH HHS
- National Science Foundation
- Norges Idrettshøgskole
Zitieren
APA
Hyler, A. R., Thomas, D. E., Kinskie, K. S., Brown, K. M., Duncan, J. L., Cemazar, J., Schultz, J., Brown, S., Shiri, F., Soper, S. A., Swami, N. S., & Davalos, R. V. (2025). Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications. ELECTROPHORESIS. https://doi.org/10.1002/elps.8113
Vancouver
Hyler AR, Thomas DE, Kinskie KS, Brown KM, Duncan JL, Cemazar J, et al. Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications. ELECTROPHORESIS. 2025. doi:10.1002/elps.8113
BibTeX
@article{Hyler2025,
author = {Hyler, Alexandra R and Thomas, Dean E and Kinskie, Kyle S and Brown, Kyle M and Duncan, Josie L and Cemazar, Jaka and Schultz, Jeff and Brown, Simeon and Shiri, Farhad and Soper, Steven A and Swami, Nathan S and Davalos, Rafael V},
title = {Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications},
journal = {ELECTROPHORESIS},
year = {2025},
doi = {10.1002/elps.8113}
}
EUVIMED