Multi‑Channel CE‑SDS: Core‑Performance Evaluation, System Suitability Test, and Method Validation in Biopharmaceutical Analysis
ELECTROPHORESIS · 20.11.2026
DOI: 10.1002/elps.70192 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 20.11.2026. Verfasst von Xinying Zhao und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Bioengineering, Beijing Polytechnic University, Beijing, China. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Capillary electrophoresis–sodium dodecyl sulfate (CE‐SDS) is the gold standard for the purity assessment of protein‐based biopharmaceuticals, yet traditional single‐capillary CE‐SDS workflows suffer from inherent throughput limitations. Commercial multi‐capillary CE platforms deliver higher analytical throughput and represent powerful tools for high‐throughput biopharmaceutical testing. As their application in biopharmaceutical characterization expands, standardized system suitability test (SST) and method validation protocols tailored to the multi‐channel CE platform are urgently needed. Herein, we evaluated the core performance of a multi‐channel CE platform and reported the first scientific and efficient CE‐SDS SST and method validation scheme for multi‐channel CE platform. First, the core performance of an 8‐channel CE platform was systematically evaluated, including analytical consistency with the well‐validated single‐channel reference CE system, intra‐instrument consistency across eight capillaries, and the absence of inter‐capillary crosstalk. SST and comprehensive CE‐SDS method validation were implemented concurrently, and all SST parameters met predefined acceptance criteria throughout the method validation sequence. The CE‐SDS method validation covered specificity, linear range, limit of quantification (LOQ), accuracy, and precision, all performed in compliance with ICH requirements. The whole workflow was completed in only a few days, fully leveraging the high‐throughput advantage of multi‐channel CE platform while ensuring robust and reliable analytical results. The protocol and experimental data herein deliver practical utility and valuable regulatory‐aligned guidance for peer laboratories and biopharmaceutical enterprises to deploy multi‐channel CE in early‐stage biologic screening, process development, quality release, and other scenarios.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Bioengineering, Beijing Polytechnic University, Beijing, China.
- SCIEX, Beijing, China.
- Zencore Biologics (Shanghai) Co., Ltd., Shanghai, China.
- SCIEX, Brea, California, USA.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zhao, X., Liu, D., Wen, X., Zhang, X., Tang, H., Li, T., & Chen, H. (2026). Multi‑Channel CE‑SDS: Core‑Performance Evaluation, System Suitability Test, and Method Validation in Biopharmaceutical Analysis. ELECTROPHORESIS. https://doi.org/10.1002/elps.70192
Vancouver
Zhao X, Liu D, Wen X, Zhang X, Tang H, Li T, et al. Multi‑Channel CE‑SDS: Core‑Performance Evaluation, System Suitability Test, and Method Validation in Biopharmaceutical Analysis. ELECTROPHORESIS. 2026. doi:10.1002/elps.70192
BibTeX
@article{Zhao2026,
author = {Zhao, Xinying and Liu, Dongke and Wen, Xikai and Zhang, Xiaoxia and Tang, Hongmei and Li, Tingting and Chen, Hongxu},
title = {Multi‑Channel CE‑SDS: Core‑Performance Evaluation, System Suitability Test, and Method Validation in Biopharmaceutical Analysis},
journal = {ELECTROPHORESIS},
year = {2026},
doi = {10.1002/elps.70192}
}