EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Carbon Nanotubes‐Ionic Liquid Composite for Electrooxidation of Trimethoprim

João Vinícius Duarte Barbosa, Vitor Lima Mesquita, Raíssa Costa de Oliveira, Janevane Silva de Castro, Pedro de Lima‐Neto, Paulo Naftali da Silva Casciano, Cristiani Lopes Capistrano Gonçalves de Oliveira, Djenaine De Souza, Adriana Nunes Correia

Electroanalysis · 2026-04 · 38 (4)

DOI: 10.1002/elan.70137 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 16.04.2026. Verfasst von João Vinícius Duarte Barbosa und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a new, simple, fast, and cost‐effectivemethod for the identification and quantification of Trimethoprim in pharmaceutical tablets. It employs an electrochemical sensor based on a glassy carbon electrode modified with 4hr functionalized multiwalled carbon nanotubes, 1‐butyl‐3‐methylimidazolium hexafluorophosphate, and Nafion. Physical characterization revealed good dispersion of modifiers across the electrode surface and a high dielectric constant. Electrochemical testing of the developedsensor was performed using the ferro/ferricyanide system, and data showed improved electron transfer, confirming its suitability as a voltammetric sensor. Experimental and voltammetric optimizations for Trimethoprim analysis revealed that the Britton–Robinson buffer at pH 5.0 was the optimal supporting electrolyte, with an accumulation potential of −0.5 V for 120 s, a potential pulse frequency of 30 s −1 , a pulse amplitude of 25 mV, and a pulse potential increment of 2 mV. Analytical curves were prepared in triplicate using the standard addition method, yielding a linear range from 0.49 to 2.49 μmol L −1 , a calculated limit of detection of 0.0970 μmol L −1 , and a limit of quantification of 0.293 μmol L −1 , which is lower than similar data obtained by traditional chromatographic procedures. The precision of the proposed procedure was evaluated using repeatability and intermediate precision, yielding a relative standard deviation of less than 2.0%, indicating a satisfactory outcome. Accuracy in pharmaceutical samples, evaluated by recovery experiments, yielded values of around 103.0%, highlighting the suitability of the developed sensor for Trimethoprim analysis.

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Barbosa, J. V. D., Mesquita, V. L., Oliveira, R. C. D., Castro, J. S. D., Lima‐Neto, P. D., Casciano, P. N. D. S., Oliveira, C. L. C. G. D., Souza, D. D., & Correia, A. N. (2026). Carbon Nanotubes‐Ionic Liquid Composite for Electrooxidation of Trimethoprim. Electroanalysis, 38(4). https://doi.org/10.1002/elan.70137

Vancouver

Barbosa JVD, Mesquita VL, Oliveira RCD, Castro JSD, Lima‐Neto PD, Casciano PNDS, et al. Carbon Nanotubes‐Ionic Liquid Composite for Electrooxidation of Trimethoprim. Electroanalysis. 2026;38(4). doi:10.1002/elan.70137

BibTeX
@article{Barbosa2026,
  author = {Barbosa, João Vinícius Duarte and Mesquita, Vitor Lima and Oliveira, Raíssa Costa de and Castro, Janevane Silva de and Lima‐Neto, Pedro de and Casciano, Paulo Naftali da Silva and Oliveira, Cristiani Lopes Capistrano Gonçalves de and Souza, Djenaine De and Correia, Adriana Nunes},
  title = {Carbon Nanotubes‐Ionic Liquid Composite for Electrooxidation of Trimethoprim},
  journal = {Electroanalysis},
  year = {2026},
  volume = {38},
  number = {4},
  doi = {10.1002/elan.70137}
}
Kostenlos starten →