EUVIMEDEUVIMED entdecken
Crossref

Amperometric Biosensor Based on a Semipermeable Poly‐ Meta ‐Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate l ‐Lactate Determination in Blood Serum

Kseniia Berketa, Anhelina Buzhak, Yevhen Vakhovskyi, Daryna Mruga, Andrii Sverstiuk, Olha Soldatkina, Olha Lyubovych, Olga Marchuk, Serhii Dzyadevych, Oleksandr Soldatkin

Electroanalysis · 2025-01 · 37 (1)

DOI: 10.1002/elan.12011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 23.01.2025. Verfasst von Kseniia Berketa und 9 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents the development and optimization of a biosensor for the accurate and rapid determination of l ‐lactate concentration in human serum samples. The biosensor uses lactate oxidase immobilized in a bovine serum albumin matrix on a platinum transducer, modified with a semipermeable m ‐polyphenylenediamine (PPD) membrane. The PPD membrane minimizes influence from solution parameters like ionic strength and protein content, as well as interferents in blood serum on an analysis result. The biosensor offers a broad linear range (7–1000 μM), low detection limit (7 μM), and short analysis time (8 min), making it suitable for real serum samples measurement. Results showed high correlation with reference methods, with a correlation coefficient of 0.982 in comparison with standard analysis method. Stability tests indicated an RSD of 2.9% and 6.7% for model and real samples analysis, with functionality sustained over 5 days. This biosensor is promising for clinical diagnostics due to its speed, accuracy, and stability in measuring l ‐lactate.

Zitieren

APA

Berketa, K., Buzhak, A., Vakhovskyi, Y., Mruga, D., Sverstiuk, A., Soldatkina, O., Lyubovych, O., Marchuk, O., Dzyadevych, S., & Soldatkin, O. (2025). Amperometric Biosensor Based on a Semipermeable Poly‐ Meta ‐Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate l ‐Lactate Determination in Blood Serum. Electroanalysis, 37(1). https://doi.org/10.1002/elan.12011

Vancouver

Berketa K, Buzhak A, Vakhovskyi Y, Mruga D, Sverstiuk A, Soldatkina O, et al. Amperometric Biosensor Based on a Semipermeable Poly‐ Meta ‐Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate l ‐Lactate Determination in Blood Serum. Electroanalysis. 2025;37(1). doi:10.1002/elan.12011

BibTeX
@article{Berketa2025,
  author = {Berketa, Kseniia and Buzhak, Anhelina and Vakhovskyi, Yevhen and Mruga, Daryna and Sverstiuk, Andrii and Soldatkina, Olha and Lyubovych, Olha and Marchuk, Olga and Dzyadevych, Serhii and Soldatkin, Oleksandr},
  title = {Amperometric Biosensor Based on a Semipermeable Poly‐ Meta ‐Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate l ‐Lactate Determination in Blood Serum},
  journal = {Electroanalysis},
  year = {2025},
  volume = {37},
  number = {1},
  doi = {10.1002/elan.12011}
}
Kostenlos starten →