Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running
International Journal of Sports Physiology and Performance · 2026
DOI: 10.1123/ijspp.2025-0382 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift International Journal of Sports Physiology and Performance, 2026. Verfasst von Cody R van Rassel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada. Hauptthemen laut MEDLINE: Running, Exercise Test, Energy Metabolism. Die Arbeit nennt 68 Literaturangaben.
Abstract (Originalsprache)
Purpose
Inertial measurement units, like the shoe-mounted Stryd running power meter, offer an alternative metric to guide endurance training. Despite its utility on level running surfaces, whether Stryd can accurately monitor training intensity for inclined running is unclear.
Methods
Ten (4 females) trained runners (28 [8] y, 55.9 [9.1] mL/kg/min) performed a Step-Ramp-Step exercise test to estimate the running power at the respiratory compensation point. On a separate visit, participants performed 5-minute running trials at 0%, 2%, 4%, 6%, and 8% inclines in a random order, with speed adjusted to elicit the running power 10% below respiratory compensation point. Metabolic power and mechanical efficiency were calculated for the final minute of each trial.
Results
Metabolic power and oxygen uptake at 6% (1063 [191] W, 3.02 [0.53] L/min) and 8% (1079 [219] W, 3.05 [0.62] L/min) were significantly higher ( P < .05 for all comparisons) than at 0% (1037 [191] W, 2.95 [0.53] L/min). Consequently, mechanical efficiency was significantly lower at 6% (21.6% [1.4%]; P = .024) and 8% (21.3% [1.3%]; P = .006) compared with 0% (22.1% [1.3%]). These variables were not different from 0% for the 2% and 4% running trials ( P > .05). Ventilation ( P = .550), breathing frequency ( P = .273), heart rate ( P = .924), and rating of perceived exertion ( P = .709) were not different across inclines.
Conclusions
Although Stryd slightly underestimated metabolic power (∼2%–4%) at steeper inclines, running at a fixed Stryd power yielded relatively consistent indications of metabolic demand across incline conditions, suggesting it is a useful metric to guide training during incline treadmill running.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada.
- Department of Sports Sciences, The University of Tokyo, Tokyo, Japan.
- Department of Sport Science, University of Innsbruck, Innsbruck, Austria.
ORCID-Profile: Cody R van Rassel, Takuya Watanabe, Diego Jaén-Carrillo, Martin J MacInnis
Zitieren
APA
van Rassel, C. R., Gow, S., Watanabe, T., Jaén-Carrillo, D., & MacInnis, M. J. (2026). Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2025-0382
Vancouver
van Rassel CR, Gow S, Watanabe T, Jaén-Carrillo D, MacInnis MJ. Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running. International Journal of Sports Physiology and Performance. 2026. doi:10.1123/ijspp.2025-0382
BibTeX
@article{vanRassel2026,
author = {van Rassel, Cody R and Gow, Scott and Watanabe, Takuya and Jaén-Carrillo, Diego and MacInnis, Martin J},
title = {Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running},
journal = {International Journal of Sports Physiology and Performance},
year = {2026},
doi = {10.1123/ijspp.2025-0382}
}