EUVIMEDEUVIMED entdecken
Validierungsstudie

Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running

Cody R van Rassel iD, Scott Gow, Takuya Watanabe iD, Diego Jaén-Carrillo iD, Martin J MacInnis iD

International Journal of Sports Physiology and Performance · 2026

DOI: 10.1123/ijspp.2025-0382 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift International Journal of Sports Physiology and Performance, 2026. Verfasst von Cody R van Rassel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada. Hauptthemen laut MEDLINE: Running, Exercise Test, Energy Metabolism. Die Arbeit nennt 68 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Inertial measurement units, like the shoe-mounted Stryd running power meter, offer an alternative metric to guide endurance training. Despite its utility on level running surfaces, whether Stryd can accurately monitor training intensity for inclined running is unclear.

Methods

Ten (4 females) trained runners (28 [8] y, 55.9 [9.1] mL/kg/min) performed a Step-Ramp-Step exercise test to estimate the running power at the respiratory compensation point. On a separate visit, participants performed 5-minute running trials at 0%, 2%, 4%, 6%, and 8% inclines in a random order, with speed adjusted to elicit the running power 10% below respiratory compensation point. Metabolic power and mechanical efficiency were calculated for the final minute of each trial.

Results

Metabolic power and oxygen uptake at 6% (1063 [191] W, 3.02 [0.53] L/min) and 8% (1079 [219] W, 3.05 [0.62] L/min) were significantly higher ( P < .05 for all comparisons) than at 0% (1037 [191] W, 2.95 [0.53] L/min). Consequently, mechanical efficiency was significantly lower at 6% (21.6% [1.4%]; P = .024) and 8% (21.3% [1.3%]; P = .006) compared with 0% (22.1% [1.3%]). These variables were not different from 0% for the 2% and 4% running trials ( P > .05). Ventilation ( P = .550), breathing frequency ( P = .273), heart rate ( P = .924), and rating of perceived exertion ( P = .709) were not different across inclines.

Conclusions

Although Stryd slightly underestimated metabolic power (∼2%–4%) at steeper inclines, running at a fixed Stryd power yielded relatively consistent indications of metabolic demand across incline conditions, suggesting it is a useful metric to guide training during incline treadmill running.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningExercise TestEnergy MetabolismHumansOxygen ConsumptionFemaleAdultMaleShoesHeart RatePhysical Endurance

Stichwörter der Autor:innen

exercise intensityexercise prescriptionwearable technology

Autor:innen und Institutionen

  • Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada.
  • Department of Sports Sciences, The University of Tokyo, Tokyo, Japan.
  • Department of Sport Science, University of Innsbruck, Innsbruck, Austria.

ORCID-Profile: Cody R van Rassel, Takuya Watanabe, Diego Jaén-Carrillo, Martin J MacInnis

Zitieren

APA

van Rassel, C. R., Gow, S., Watanabe, T., Jaén-Carrillo, D., & MacInnis, M. J. (2026). Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2025-0382

Vancouver

van Rassel CR, Gow S, Watanabe T, Jaén-Carrillo D, MacInnis MJ. Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running. International Journal of Sports Physiology and Performance. 2026. doi:10.1123/ijspp.2025-0382

BibTeX
@article{vanRassel2026,
  author = {van Rassel, Cody R and Gow, Scott and Watanabe, Takuya and Jaén-Carrillo, Diego and MacInnis, Martin J},
  title = {Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2026},
  doi = {10.1123/ijspp.2025-0382}
}
Kostenlos starten →