EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling

James G Hopker iD, Callum Barnes, Christopher R J Fennell, Stuart Gibson

European Journal of Sport Science · 2025-12 · 25 (12)

DOI: 10.1002/ejsc.70098 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift European Journal of Sport Science, online erschienen am 28.11.2025. Verfasst von James G Hopker und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Natural Sciences, University of Kent, Canterbury, UK. Hauptthemen laut MEDLINE: Bicycling, Sports Equipment, Athletic Performance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovate UK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cycling performance is strongly influenced by aerodynamics, with most resistive drag forces being attributed to the rider. The Body Rocket device (BR) is an on‐bike sensor system that uses the same load cell technology as a wind tunnel, directly measuring real‐time aerodynamic resistance (CdA) from the rider. This study aimed to measure the validity and reliability of CdA measures from BR in two experiments. In Experiment 1, validity of BR was assessed in wind tunnel with a rod and discs of known diameter attached to the end change CdA by a known amount. Experiment 2, examined the validity and reliability of BR in a 250m indoor velodrome. Ten cyclists performed 7 identical efforts at ∼40 km/h for 10 laps of the velodrome, the first 4 to assess validity with the same rod and discs used in the wind tunnel, with the remaining 3 without changes in resistance or the riders changing position to assess reliability. Validity results demonstrated BR measured CdA to be strongly correlated with calculated CdA from the disc addition ( r = 0.99), with the smallest identified changes being 0.002 m 2 across wind tunnel and velodrome. Good agreement was found between theoretical and measured CdA with varying disc sizes (95% limits of agreement = −0.012 to 0.009 m 2 ). A high level of reliability was demonstrated during Experiment 2 with strong intraclass correlation (0.99) and small coefficient of variation (1.67%). Findings of this study demonstrate BR is a valid and reliable device for measuring real‐time CdA during cycling in an indoor velodrome.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BicyclingSports EquipmentAthletic PerformanceHumansReproducibility of ResultsMaleAdultYoung AdultBiomechanical PhenomenaEquipment Design

Stichwörter der Autor:innen

coefficient dragperformancetestingtime trialwind tunnel

Autor:innen und Institutionen

  • School of Natural Sciences, University of Kent, Canterbury, UK.
  • School of Engineering, Maths and Physics, University of Kent, Canterbury, UK.

ORCID-Profile: James G Hopker

Förderung

  • Innovate UK

Zitieren

APA

Hopker, J. G., Barnes, C., Fennell, C. R. J., & Gibson, S. (2025). Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling. European Journal of Sport Science, 25(12). https://doi.org/10.1002/ejsc.70098

Vancouver

Hopker JG, Barnes C, Fennell CRJ, Gibson S. Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling. European Journal of Sport Science. 2025;25(12). doi:10.1002/ejsc.70098

BibTeX
@article{Hopker2025,
  author = {Hopker, James G and Barnes, Callum and Fennell, Christopher R J and Gibson, Stuart},
  title = {Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling},
  journal = {European Journal of Sport Science},
  year = {2025},
  volume = {25},
  number = {12},
  doi = {10.1002/ejsc.70098}
}
Kostenlos starten →