Validierungsstudie in der Zeitschrift European Journal of Sport Science, 2024. Verfasst von Keenan B MacDougall und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Muscle Fatigue, Bicycling, Quadriceps Muscle, Electric Stimulation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The measurement of skeletal muscle fatigue in response to cycling exercise is commonly done in isometric conditions, potentially limiting its ecological validity, and creating challenges in monitoring the time course of muscle fatigue across an exercise bout. This study aimed to determine if muscle fatigue could be reliably assessed by measuring quadriceps twitch force evoked while pedaling, using instrumented pedals. Nine participants completed three laboratory visits: a step incremental test to determine power output at lactate threshold, and on separate occasions, two constant‐intensity bouts at a power output 10% above lactate threshold. Femoral nerve electrical stimulation was applied to elicit quadriceps twitch force both while pedaling (dynamic) and at rest (isometric). The test–retest reliability of the dynamic twitch forces and the agreement between the dynamic and isometric twitch forces were evaluated. Dynamic twitch force was found to have excellent reliability in an unfatigued state (intraclass correlation coefficient (ICC) = 0.920 and mean coefficient of variation (CV) = 7.5%), and maintained good reliability at task failure (ICC = 0.846 and mean CV = 11.5%). When comparing dynamic to isometric twitch forces across the task, there was a greater relative decline in the dynamic condition ( P = 0.001). However, when data were normalized to the 5 min timepoint when potentiation between conditions was presumed to be more similar, this difference disappeared ( P = 0.207). The reliability of this method was shown to be commensurate with the gold standard method utilizing seated isometric dynamometers and offers a new avenue to monitor the kinetics of muscle fatigue during cycling in real time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle FatigueBicyclingQuadriceps MuscleElectric StimulationIsometric ContractionHumansReproducibility of ResultsMaleYoung AdultAdultFemoral NerveFemaleExercise Test

Stichwörter der Autor:innen

cycling exercisedynamic muscle functionmuscle contractile functionnerve stimulationskeletal muscle fatigue

Autor:innen und Institutionen

  • Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.

ORCID-Profile: Keenan B MacDougall

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

MacDougall, K. B., Aboodarda, S. J., Westergard, P. H., & MacIntosh, B. R. (2024). The validity and reliability of quadriceps twitch force as a measure of skeletal muscle fatigue while cycling. European Journal of Sport Science. https://doi.org/10.1002/ejsc.12181

Vancouver

MacDougall KB, Aboodarda SJ, Westergard PH, MacIntosh BR. The validity and reliability of quadriceps twitch force as a measure of skeletal muscle fatigue while cycling. European Journal of Sport Science. 2024. doi:10.1002/ejsc.12181

BibTeX
@article{MacDougall2024,
  author = {MacDougall, Keenan B and Aboodarda, Saied J and Westergard, Paulina H and MacIntosh, Brian R},
  title = {The validity and reliability of quadriceps twitch force as a measure of skeletal muscle fatigue while cycling},
  journal = {European Journal of Sport Science},
  year = {2024},
  doi = {10.1002/ejsc.12181}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche