EUVIMEDObjevte EUVIMED
Open access · CC BY-NC-ND 4.0

Usefulness of Oxygen Uptake Efficiency Slope in a 6 Min Walk Test in Chronic Heart Failure

Min Sun Kim iD, Woori Bong, Jung Hyun Choi iD, Myung-Jun Shin, Byeong-Ju Lee iD

ESC Heart Failure · 2024-08-01 · 11 (4) · 2055-2062

DOI: 10.1002/ehf2.14754 ↗

At a glance

Journal article in ESC Heart Failure, published online on 2024-03-26. Written by Min Sun Kim and 4 co-authors. Institution: Division of Cardiology, Department of Internal Medicine, Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea. Major MEDLINE topics: Heart Failure, Oxygen Consumption, Walk Test, Exercise Tolerance. Cited 3 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Aims

Frailty is an obstacle to performing cardiopulmonary exercise test (CPET) in patients with chronic heart failure (CHF). We evaluated the usefulness of oxygen uptake efficiency slope (OUES) using a 6 min walk test (6MWT) with portable gas analysis compared with CPET-derived parameters in patients with CHF. Methods and results Patients with CHF who underwent both the 6MWT with portable gas analysis and CPET between December 2016 and May 2020 were retrospectively investigated. The 6MWT-derived and echocardiographic parameters were compared with the OUES and peak oxygen consumption (VO2) from the CPET. Forty patients were analysed; 50% were male with a mean age of 55.45 ± 14.70 years. Twenty-six patients (65%) had New York Heart Association Functional Classification II or III dyspnoea. Twenty-five patients (62.5%) had heart failure (HF) with preserved ejection fraction (EF) (left ventricular EF > 50%), and nine patients (22.5%) had HF with reduced EF (EF < 40%). During the 6MWT, the peak VO2 was 14.97 ± 3.80 mL/kg/min, which was only 74% of the peak VO2 in the CPET, 20.18 ± 5.64 mL/kg/min. The OUES in the 6MWT was lower than that in the CPET (1528.87 ± 579.01 in the 6MWT vs. 1638.69 ± 601.31 in the CPET). The 6 min walk distance (6MWD) and OUES in the 6MWT were positively correlated with the OUES in the CPET (6MWD, r = 0.434, P = 0.005; OUES, r = 0.729, P < 0.001). The OUES in the 6MWT showed the strongest correlation with the OUES in the CPET. When we divided patients into two groups according to peak VO2 in the CPET, the correlation between OUES values of the 6MWT and that of the CPET was consistently confirmed (peak VO2 ≥ 20 mL/kg/min group, r = 0.661, P = 0.001; peak VO2 < 20 mL/kg/min group, r = 0.526, P = 0.021). In addition, the 6MWD, OUES, and peak VO2 in the 6MWT were associated with peak VO2 in the CPET (6MWD, r = 0.627, P < 0.001; OUES, r = 0.452, P = 0.003; and peak VO2, r = 0.492, P = 0.001).

Conclusions

In frail patients with CHF who have difficulty performing maximal exercises, the OUES through the 6MWT may be applied instead of the OUES and peak VO2 from the CPET.

Subjects

MeSH terms (MEDLINE)

Heart FailureOxygen ConsumptionWalk TestExercise ToleranceHumansMaleFemaleMiddle AgedRetrospective StudiesChronic DiseaseStroke VolumeEchocardiographyExercise TestFollow-Up StudiesVentricular Function, LeftAged

Author keywords

Cardiopulmonary exercise testHeart failureSix‐minute walk test

Authors and institutions

  • Division of Cardiology, Department of Internal Medicine, Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine, Busan Veterans Hospital, Busan, Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.
  • Department of Rehabilitation Medicine, Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.

ORCID profiles: Min Sun Kim, Jung Hyun Choi, Byeong-Ju Lee

Cite

APA

Kim, M. S., Bong, W., Choi, J. H., Shin, M. J., & Lee, B. J. (2024). Usefulness of Oxygen Uptake Efficiency Slope in a 6 Min Walk Test in Chronic Heart Failure. ESC Heart Failure, 11(4), 2055-2062. https://doi.org/10.1002/ehf2.14754

Vancouver

Kim MS, Bong W, Choi JH, Shin MJ, Lee BJ. Usefulness of Oxygen Uptake Efficiency Slope in a 6 Min Walk Test in Chronic Heart Failure. ESC Heart Failure. 2024;11(4):2055-2062. doi:10.1002/ehf2.14754

BibTeX
@article{Kim2024,
  author = {Kim, Min Sun and Bong, Woori and Choi, Jung Hyun and Shin, Myung-Jun and Lee, Byeong-Ju},
  title = {Usefulness of Oxygen Uptake Efficiency Slope in a 6 Min Walk Test in Chronic Heart Failure},
  journal = {ESC Heart Failure},
  year = {2024},
  volume = {11},
  number = {4},
  pages = {2055--2062},
  doi = {10.1002/ehf2.14754}
}
Start for free →