EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application

Karla A O Souza, Náthaly C B F Santos iD, Rafael Lanaro iD, Sara E Walton iD, Alex J Krotulski iD, Barry K Logan iD, Mauricio Yonamine, Jose Luiz Costa iD

Drug Testing and Analysis · 2026

DOI: 10.1002/dta.70126 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Drug Testing and Analysis, 2026. Verfasst von Karla A O Souza und 7 weiteren Autor:innen. Beteiligte Einrichtung: Centro de Informação e Assistência Toxicológica de Campinas (CIATox-Campinas), Universidade Estadual de Campinas (UNICAMP), Campinas, SP, Brazil. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Analgesics, Opioid. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nitazenes are highly potent synthetic opioids of increasing concern in clinical and forensic toxicology, thus underscoring the need for sensitive and selective analytical methods for biological specimens. This study describes the development and validation of an LC–MS/MS method for the quantification of nitazene analogs and related metabolites in plasma using micro‐QuEChERS sample preparation. The validated concentration range was 0.05–20 ng/mL, with coefficients of determination R 2 > 0.99. The limit of detection (LOD) was 0.025 ng/mL, and the lower limit of quantification (LLOQ) was 0.05 ng/mL. Bias ranged from −2.6% to 15.7%, within‐run precision from 3.4% to 12.7%, and between‐run precision from 4.4% to 14.9%, as evaluated at three quality control levels. Matrix effects and recovery were analyte‐dependent but compatible with satisfactory overall validation performance. No interferences or carryover were observed. Method applicability was demonstrated in an authentic intoxication case, in which N ‐pyrrolidino protonitazene was quantified at 1.4 ng/mL, representing, to our knowledge, the first clinical case reported in Brazil. The case was clinically characterized by severe opioid toxicity requiring repeated naloxone administration. The proposed method combined low sample volume, simple sample preparation, and suitable analytical performance for targeted analysis of emerging nitazene compounds. These findings support the use of micro‐QuEChERS and LC–MS/MS as a practical approach for targeted nitazene quantification in clinical and forensic toxicology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryAnalgesics, OpioidHumansLiquid Chromatography-Mass SpectrometryLimit of DetectionSubstance Abuse DetectionReproducibility of ResultsChromatography, LiquidBenzimidazoles

Stichwörter der Autor:innen

LC–MS/MSmicro‐QuEChERSnitazenesplasmatoxicology

Substanzen

Analgesics, OpioidnitazeneBenzimidazoles

Autor:innen und Institutionen

  • Centro de Informação e Assistência Toxicológica de Campinas (CIATox-Campinas), Universidade Estadual de Campinas (UNICAMP), Campinas, SP, Brazil.
  • Faculdade de Ciências Médicas, Universidade Estadual de Campinas (UNICAMP), Campinas, SP, Brazil.
  • Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, Horsham, Pennsylvania, USA.
  • NMS Labs, Horsham, Pennsylvania, USA.
  • Faculty of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP, Brazil.
  • Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas (UNICAMP), Campinas, SP, Brazil.

ORCID-Profile: Náthaly C B F Santos, Rafael Lanaro, Sara E Walton, Alex J Krotulski, Barry K Logan, Jose Luiz Costa

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Souza, K. A. O., Santos, N. C. B. F., Lanaro, R., Walton, S. E., Krotulski, A. J., Logan, B. K., Yonamine, M., & Costa, J. L. (2026). Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application. Drug Testing and Analysis. https://doi.org/10.1002/dta.70126

Vancouver

Souza KAO, Santos NCBF, Lanaro R, Walton SE, Krotulski AJ, Logan BK, et al. Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application. Drug Testing and Analysis. 2026. doi:10.1002/dta.70126

BibTeX
@article{Souza2026,
  author = {Souza, Karla A O and Santos, Náthaly C B F and Lanaro, Rafael and Walton, Sara E and Krotulski, Alex J and Logan, Barry K and Yonamine, Mauricio and Costa, Jose Luiz},
  title = {Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application},
  journal = {Drug Testing and Analysis},
  year = {2026},
  doi = {10.1002/dta.70126}
}
Kostenlos starten →