EUVIMEDObjevte EUVIMED
Crossref

Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin — Implementation of an improved workflow

Stacey Richards iD, David Palmer iD, Adam Cawley iD, Martin Wainscott, John Keledjian

Drug Testing and Analysis · 2025

DOI: 10.1002/dta.3785 ↗

At a glance

Journal article in Drug Testing and Analysis, 2025. Written by Stacey Richards and 4 co-authors. Institution: Australian Racing Forensic Laboratory, Racing NSW, Sydney, NSW, Australia. Major MEDLINE topics: Erythropoietin, Substance Abuse Detection. Cited 2 times so far (Crossref); 38 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

An improved screening workflow and a robust capillary flow LC–MS confirmatory method for the detection of recombinant human erythropoietin (rHuEPO) has been implemented to increase the sensitivity of rHuEPO detection and to reduce the number of suspect samples committed to confirmatory testing. The influence of repeated dosing of epoetin‐β on the detection window of rHuEPO in equine plasma was assessed using the optimised method. Samples were initially assessed using an economical R&D Human EPO Duo‐Set ELISA Development System. Samples indicating a result greater than the batch baseline were analysed using the complementary R&D Human EPO Quantikine IVD ELISA kit. All samples recording an abnormal screening result were subjected to confirmatory analysis. Confirmation of rHuEPO in plasma (≥2.5 ml) in the range of 4–13 mIU/ml (n = 6) was achieved using immunoaffinity enrichment, tryptic digestion, and capillary flow LC–MS/MS. Four horses were administered a single dose of epoetin‐β (10,000 IU) via the subcutaneous and intravenous routes, on two occasions, seven days apart. The excretion profile was rapid with epoetin‐β detection times of 48 to 72 h following each administration, with no appreciable difference observed between the two routes of administration. This workflow has been shown as an effective anti‐doping strategy related to rHuEPO misuse and supports the use of out‐of‐competition testing of horses in the 2 to 3‐day period prior to race‐day.

Subjects

MeSH terms (MEDLINE)

ErythropoietinSubstance Abuse DetectionAnimalsHorsesRecombinant ProteinsTandem Mass SpectrometryHumansChromatography, LiquidEnzyme-Linked Immunosorbent AssayDoping in SportsWorkflowLimit of Detection

Author keywords

capillary LC–MS/MSequine plasmaerythropoietinproteotypic peptides

Substances

ErythropoietinRecombinant Proteinsepoetin betaEPO protein, human

Authors and institutions

  • Australian Racing Forensic Laboratory, Racing NSW, Sydney, NSW, Australia.
  • New Zealand Racing Laboratory Services Ltd, Avondale, Auckland, New Zealand.
  • Harness Racing NSW, Bankstown, NSW, Australia.

ORCID profiles: Stacey Richards, David Palmer, Adam Cawley

Cite

APA

Richards, S., Palmer, D., Cawley, A., Wainscott, M., & Keledjian, J. (2025). Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin — Implementation of an improved workflow. Drug Testing and Analysis. https://doi.org/10.1002/dta.3785

Vancouver

Richards S, Palmer D, Cawley A, Wainscott M, Keledjian J. Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin — Implementation of an improved workflow. Drug Testing and Analysis. 2025. doi:10.1002/dta.3785

BibTeX
@article{Richards2025,
  author = {Richards, Stacey and Palmer, David and Cawley, Adam and Wainscott, Martin and Keledjian, John},
  title = {Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin — Implementation of an improved workflow},
  journal = {Drug Testing and Analysis},
  year = {2025},
  doi = {10.1002/dta.3785}
}
Start for free →