EUVIMEDEUVIMED entdecken
Crossref

Elucidating important factors and corresponding method optimization for sensitive detection of small peptide drugs in human urine by solid‐phase extraction and UPLC‐HRMS: The influence of MS scan modes, protein precipitants, and ammonium formate

Yunxi Liu iD, Congcong Ma, Tianyu Dong, Kuan Yan, Genye He, Zhanliang Wang, Yufeng Zhang, Lu Liu, Wei Chang iD

Drug Testing and Analysis · 2025-04 · 17 (4) · 457-469

DOI: 10.1002/dta.3746 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Drug Testing and Analysis, online erschienen am 12.06.2024. Verfasst von Yunxi Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Anti-Doping Laboratory, Beijing Sport University, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Solid Phase Extraction, Substance Abuse Detection, Peptides, Performance-Enhancing Substances. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Small peptide hormones are widely used in sports as performance‐enhancing substances, making it crucial to develop sensitive analytical methods for their detection in doping control analysis. Various factors significantly affect analytical sensitivity, such as the selection of ultra‐performance liquid chromatography (UPLC) mobile phase, high‐resolution mass spectrometry (HRMS) scanning modes, and extraction solvents for pretreatment. Herein, comparative study approach was utilized to investigate the sensitivity of each peptide analyte under both full scan and parallel reaction monitoring (PRM) modes of HRMS and assess the effects of some protein precipitants as a part of extraction solvents on solid‐phase extraction (SPE). The results showed that full scan should be selected as the primary scan mode of HRMS, and the combination with PRM mode could effectively compensate for the limitations of full scan, and the addition of protein precipitants would adversely affect the detection of certain small peptide analytes. Meanwhile, influences of ammonium formate in reverse UPLC mobile phase on the charge state distribution of small peptides were investigated and elucidated. Based on these findings, a sensitive and reliable UPLC‐HRMS analytical method combining full scan and PRM mode was validated for screening and confirmation of 63 small peptide analytes after SPE, with limits of detection (LODs) ranging between 0.010 and 0.473 ng/ml and limits of identification (LOIs) ranging between 0.015 and 1.512 ng/ml. Additionally, suggestions were provided for the detection of [Arg8]‐vasopressin, dermorphin, and its analogues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase ExtractionSubstance Abuse DetectionPeptidesPerformance-Enhancing SubstancesHumansChromatography, High Pressure LiquidLimit of DetectionDoping in SportsFormatesMass SpectrometryTandem Mass Spectrometry

Stichwörter der Autor:innen

UPLC‐HRMSammonium formateprotein precipitantsscanning modessmall peptides

Substanzen

Formatesformic acidPeptidesPerformance-Enhancing Substances

Autor:innen und Institutionen

  • Beijing Anti-Doping Laboratory, Beijing Sport University, Beijing, People's Republic of China.

ORCID-Profile: Yunxi Liu, Wei Chang

Zitieren

APA

Liu, Y., Ma, C., Dong, T., Yan, K., He, G., Wang, Z., Zhang, Y., Liu, L., & Chang, W. (2025). Elucidating important factors and corresponding method optimization for sensitive detection of small peptide drugs in human urine by solid‐phase extraction and UPLC‐HRMS: The influence of MS scan modes, protein precipitants, and ammonium formate. Drug Testing and Analysis, 17(4), 457-469. https://doi.org/10.1002/dta.3746

Vancouver

Liu Y, Ma C, Dong T, Yan K, He G, Wang Z, et al. Elucidating important factors and corresponding method optimization for sensitive detection of small peptide drugs in human urine by solid‐phase extraction and UPLC‐HRMS: The influence of MS scan modes, protein precipitants, and ammonium formate. Drug Testing and Analysis. 2025;17(4):457-469. doi:10.1002/dta.3746

BibTeX
@article{Liu2025,
  author = {Liu, Yunxi and Ma, Congcong and Dong, Tianyu and Yan, Kuan and He, Genye and Wang, Zhanliang and Zhang, Yufeng and Liu, Lu and Chang, Wei},
  title = {Elucidating important factors and corresponding method optimization for sensitive detection of small peptide drugs in human urine by solid‐phase extraction and UPLC‐HRMS: The influence of MS scan modes, protein precipitants, and ammonium formate},
  journal = {Drug Testing and Analysis},
  year = {2025},
  volume = {17},
  number = {4},
  pages = {457--469},
  doi = {10.1002/dta.3746}
}
Kostenlos starten →