Broad‐spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high‐resolution mass spectrometry
Rapid Communications in Mass Spectrometry · 2024
DOI: 10.1002/rcm.9856 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Taiga Uchida und 5 weiteren Autor:innen. Beteiligte Einrichtung: Drug Analysis Department, Laboratory of Racing Chemistry, Utsunomiya, Japan. Hauptthemen laut MEDLINE: Doping in Sports, Limit of Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Japan Racing Association.
Abstract (Originalsprache)
Rationale
To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine.
Methods
The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid‐phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed‐phase column and analyzed using liquid chromatography/high‐resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run.
Results
The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples.
Conclusions
We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub‐ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full‐scan mode.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Drug Analysis Department, Laboratory of Racing Chemistry, Utsunomiya, Japan.
ORCID-Profile: Taiga Uchida, Hideaki Ishii, Gary Ngai-Wa Leung
Förderung
- Japan Racing Association
Zitieren
APA
Uchida, T., Kisugi, T., Ishii, H., Yamada, M., Kinoshita, K., & Leung, G. N. (2024). Broad‐spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9856
Vancouver
Uchida T, Kisugi T, Ishii H, Yamada M, Kinoshita K, Leung GN. Broad‐spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9856
BibTeX
@article{Uchida2024,
author = {Uchida, Taiga and Kisugi, Takaya and Ishii, Hideaki and Yamada, Masayuki and Kinoshita, Kenji and Leung, Gary Ngai-Wa},
title = {Broad‐spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high‐resolution mass spectrometry},
journal = {Rapid Communications in Mass Spectrometry},
year = {2024},
doi = {10.1002/rcm.9856}
}
EUVIMED