Quantitative analysis of drugs of abuse and cognitive enhancers in influent wastewater by means of two chromatographic methods
Drug Testing and Analysis · 2024
DOI: 10.1002/dta.3608 ↗At a glance
Validierungsstudie in Drug Testing and Analysis, 2024. Written by Fabian Frankenfeld and 3 co-authors. Institution: Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signalin…. Major MEDLINE topics: Wastewater, Illicit Drugs, Tandem Mass Spectrometry, Water Pollutants, Chemical. Cited 6 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Sewage‐based epidemiology using influent wastewater is used to estimate the consumption trends of (illicit) drugs over a short or long period of time in a subpopulation. The current study aimed to develop two separate methods for the quantitative analysis of selected drugs of abuse (DOA) and cognitive enhancers in influent wastewater using reversed‐phase (RP) or hydrophilic interaction liquid chromatography (HILIC) coupled to high‐resolution tandem mass spectrometry (LC‐HRMS/MS). The performance of RP and HILIC column was evaluated. A simple solid phase extraction was used for sample preparation. Short runtimes of 10 and 15 min on the RP and the HILIC column, respectively, allowed sufficient throughput. A six‐point calibration was used for quantification with calibration ranges between 10 and 100 ng/L for all analytes except for benzoylecgonine (BZE, 30–300 ng/L). Method validation was performed according to ICH guideline M10. Analytes such as amphetamine (AMPH), BZE, cocaethylene (CE), cocaine (COC), ethyl sulfate, 4‐hydroxy‐3‐methoxymethamphetamine, 3,4‐methylenedioxymethamphetamine (MDMA), methamphetamine, methylphenidate (MPH), and ritalinic acid (RA) were included in method development and validation. Two different column types were necessary for sufficient chromatographic resolution. The analytical setup allowed detection of all other analytes at concentration levels between 1 ng/L for methylphenidate to 10 ng/L for amphetamine. A method for the detection and quantification of DOA, cognitive enhancers, and their biomarkers in wastewater was successfully developed and validated. Moreover, six proof‐of‐concept samples were analyzed in which AMPH, BZE, COC, MDMA, MPH, and RA were identified and further quantified.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Homburg, Germany.
ORCID profiles: Lea Wagmann, Markus R Meyer
Cite
APA
Frankenfeld, F., Wagmann, L., Jacobs, C. M., & Meyer, M. R. (2024). Quantitative analysis of drugs of abuse and cognitive enhancers in influent wastewater by means of two chromatographic methods. Drug Testing and Analysis. https://doi.org/10.1002/dta.3608
Vancouver
Frankenfeld F, Wagmann L, Jacobs CM, Meyer MR. Quantitative analysis of drugs of abuse and cognitive enhancers in influent wastewater by means of two chromatographic methods. Drug Testing and Analysis. 2024. doi:10.1002/dta.3608
BibTeX
@article{Frankenfeld2024,
author = {Frankenfeld, Fabian and Wagmann, Lea and Jacobs, Cathy M and Meyer, Markus R},
title = {Quantitative analysis of drugs of abuse and cognitive enhancers in influent wastewater by means of two chromatographic methods},
journal = {Drug Testing and Analysis},
year = {2024},
doi = {10.1002/dta.3608}
}
EUVIMED