Comparison of two methods for the extraction of ethylglucuronide from hair

Eleonora Groff, Manuela Lucchiari, Giulia Stocchero iD, Flora Donini, Giovanni Michele Marchio, Francesco Ingenito, Lucia Bertoldi, Lucia Pecoraro, Elisabetta Bertol, Donata Favretto iD, Adriano Anesi

Drug Testing and Analysis · 2024-01 · 16 (1) · 65-70

DOI: 10.1002/dta.3516 ↗

At a glance

Journal article in Drug Testing and Analysis, published online on 2023-05-26. Written by Eleonora Groff and 10 co-authors. Institution: Toxicology Laboratory Unit, Multi-zone Operating Unit Clinical Pathology Laboratory, Department of Laboratories, APSS of Trento, Trento, Italy. Major MEDLINE topics: Tandem Mass Spectrometry, Alcoholism. Cited 2 times so far (Crossref); 11 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The aim was the comparison between the Society of Hair Testing (SoHT) consensus for the use of alcohol markers which powdering hair for the extraction of ethylglucuronide (EtG) in water and extraction using the patented M3 Reagent Test kit on cut hair. Hair samples were cut into small segments and washed twice with methanol and diethyl ether. The SoHT‐Consensus entails the extraction of pulverised hair in water. This is obtained by incubation of 25 mg of hair at room temperature overnight and 2 h sonication, even if the overnight incubation is not mandatory. The M3 method entails incubation of 25 mg of cut hair with the M3‐Reagent at 100°C for 60 min. After centrifugation, the supernatant is injected into a liquid chromatography‐tandem mass spectrometry (LC–MS/MS). Samples (191) were collected in the APSS laboratory in Trento, Italy, between 2021 and 2022. The limit of quantification (LOQ) was set at 5 pg/mg for the pulverised and M3‐Reagent methods. Assays showed good linearity above the range of LOQ‐300 pg/mg. Precision (within 20%) values were also obtained using both methods. In the Passing–Bablock linear regression, the final regression curve between M3 ( y ) and the pulverising method ( x ) showed good agreement; the Bland–Altman analysis did not show any significant bias between the two methods. The M3‐Reagent method, due to cut hair use, is easy to perform, saves time and allows for a smaller sample quantity loss with use of nondisposable grinding jars for the ball mill to obtain the extraction of EtG.

Subjects

MeSH terms (MEDLINE)

Tandem Mass SpectrometryAlcoholismHumansChromatography, LiquidHairGlucuronatesWaterSubstance Abuse Detection

Author keywords

EtGLC-MS/MScomparisoncut hairpowdered hair

Substances

ethyl glucuronideGlucuronatesWater

Authors and institutions

  • Toxicology Laboratory Unit, Multi-zone Operating Unit Clinical Pathology Laboratory, Department of Laboratories, APSS of Trento, Trento, Italy.
  • Forensic Toxicology Division, Department of Health Science, University of Firenze, Florence, Italy.
  • Research Unit U.R.I.To.N., University of Firenze, Florence, Italy.
  • Legal Medicine and Toxicology, University Hospital of Padova, Padova, Italy.

ORCID profiles: Giulia Stocchero, Donata Favretto

Cite

APA

Groff, E., Lucchiari, M., Stocchero, G., Donini, F., Marchio, G. M., Ingenito, F., Bertoldi, L., Pecoraro, L., Bertol, E., Favretto, D., & Anesi, A. (2024). Comparison of two methods for the extraction of ethylglucuronide from hair. Drug Testing and Analysis, 16(1), 65-70. https://doi.org/10.1002/dta.3516

Vancouver

Groff E, Lucchiari M, Stocchero G, Donini F, Marchio GM, Ingenito F, et al. Comparison of two methods for the extraction of ethylglucuronide from hair. Drug Testing and Analysis. 2024;16(1):65-70. doi:10.1002/dta.3516

BibTeX
@article{Groff2024,
  author = {Groff, Eleonora and Lucchiari, Manuela and Stocchero, Giulia and Donini, Flora and Marchio, Giovanni Michele and Ingenito, Francesco and Bertoldi, Lucia and Pecoraro, Lucia and Bertol, Elisabetta and Favretto, Donata and Anesi, Adriano},
  title = {Comparison of two methods for the extraction of ethylglucuronide from hair},
  journal = {Drug Testing and Analysis},
  year = {2024},
  volume = {16},
  number = {1},
  pages = {65--70},
  doi = {10.1002/dta.3516}
}
Start for free →