Improving Operator Depth Vision in Gastrointestinal Endoscopy: A Pilot Study of a New Three‐dimensional Imaging System
DEN Open · 2026-04 · 6 (1)
DOI: 10.1002/deo2.70174 ↗At a glance
Journal article in DEN Open, published online on 2025-07-16. Written by Xiaoqing Lin and 22 co-authors. Institution: Department of Gastrointestinal Endoscopy NTT Medical Center Tokyo Japan. Cited 1 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background and aims Traditional two‐dimensional (2D) gastrointestinal endoscopy lacks depth perception, leading to potential diagnostic errors. This study evaluates a novel software‐based three‐dimensional (3D) endoscopy system that converts 2D images into 3D, compatible with existing endoscopes.
Methods
A randomized comparative study was conducted with 32 endoscopists at NTT Medical Center. Participants were assigned to perform snaring tasks using either 2D or 3D imaging in short‐ and long‐distance scenarios. Success rates in first attempts were compared between the two groups.
Results
In the long‐distance scenario, the first‐attempt success rate was significantly higher in the 3D group (53.13%) compared to the 2D group (21.88%, p = 0.01). The 3D system provided a notable improvement in depth perception and distance judgment, especially for less experienced endoscopists. No significant difference was observed in the time per attempt between the two groups.
Conclusions
The new 3D system enhances depth perception and distance judgment, particularly benefiting less experienced endoscopists.
Subjects
Author keywords
Authors and institutions
- Department of Gastrointestinal Endoscopy NTT Medical Center Tokyo Japan.
- Department of Gastroenterology and Hepatology The First Affiliated Hospital Sun Yat-sen University Guangzhou China.
- Department of Medicine Haukeland University Hospital Bergen Norway.
- Division of Gastroenterology Itabashi Chuo Medical Center Tokyo Japan.
- Yokohama Sakae Kyosai Hospital Federation of National Public Service Personnel Mutual Associations Yokohama Japan.
- Department of Gastroenterology Omori Red Cross Hospital Tokyo Japan.
ORCID profiles: Xiaoqing Lin, Ken Ohata, Hiroshi Yamazaki, Hideyuki Chiba
Cite
APA
Lin, X., Ono, K., Ohata, K., Yamabe, E., Eida, H., Kanamori, M., Tomita, N., Iida, T., Banjoya, S., Kimura, T., Yamazaki, H., Furuta, K., Takeuchi, N., Kimoto, Y., Kano, Y., Minato, Y., Takayanagi, S., Nagae, S., Ito, Y., …, & Ding, Z. (2026). Improving Operator Depth Vision in Gastrointestinal Endoscopy: A Pilot Study of a New Three‐dimensional Imaging System. DEN Open, 6(1). https://doi.org/10.1002/deo2.70174
Vancouver
Lin X, Ono K, Ohata K, Yamabe E, Eida H, Kanamori M, et al. Improving Operator Depth Vision in Gastrointestinal Endoscopy: A Pilot Study of a New Three‐dimensional Imaging System. DEN Open. 2026;6(1). doi:10.1002/deo2.70174
BibTeX
@article{Lin2026,
author = {Lin, Xiaoqing and Ono, Kohei and Ohata, Ken and Yamabe, Etsuko and Eida, Hidenori and Kanamori, Miyuzen and Tomita, Naoki and Iida, Toshifumi and Banjoya, Susumu and Kimura, Tomoya and Yamazaki, Hiroshi and Furuta, Koichi and Takeuchi, Nao and Kimoto, Yoshiaki and Kano, Yuki and Minato, Yohei and Takayanagi, Shunya and Nagae, Shinya and Ito, Yohei and Negishi, Ryoju and Sakai, Eiji and Chiba, Hideyuki and Ding, Zhen},
title = {Improving Operator Depth Vision in Gastrointestinal Endoscopy: A Pilot Study of a New Three‐dimensional Imaging System},
journal = {DEN Open},
year = {2026},
volume = {6},
number = {1},
doi = {10.1002/deo2.70174}
}
EUVIMED