EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Long‐term results of palliative placement of very low‐axial force self‐expandable metallic stents for malignant colorectal obstruction

Rika Kyo iD, Takashi Sasaki, Shuntaro Yoshida, Hiroyuki Isayama iD, Tomonori Yamada, Toshiyuki Enomoto, Yorinobu Sumida, Toshio Kuwai, Masafumi Tomita, Takeaki Matsuzawa, Rintaro Moroi iD, Toshiyasu Shiratori und 1 weitere

DEN Open · 2026-04 · 6 (1)

DOI: 10.1002/deo2.70126 ↗

Kurz gefasst

Fachartikel in der Zeitschrift DEN Open, online erschienen am 01.05.2025. Verfasst von Rika Kyo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology Saiseikai Yokohamashi-Nanbu Hospital Kanagawa Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Stent placement is a standard option for palliative decompression in patients with malignant colorectal obstruction. Long‐term stent placement is associated with perforation, migration, and stent occlusion. Perforation is associated with life expectancy. Several studies have shown that stents with a high axial force (AF), which is defined as the force required to maintain the stent straight after it has bent, are associated with a higher perforation rate. Therefore, we evaluated the long‐term outcomes of using a very low AF stent (Niti‐S Enteral Colonic Uncovered stent D‐type) for palliative purposes.

Methods

Eighty‐one consecutive patients with malignant colorectal obstruction in 33 medical institutions were evaluated. A stent with very low AF was placed using an endoscope system. We evaluated the adverse events (including perforation, migration, and stent occlusion), 1‐year survival rate, and cumulative patency rate. Univariate analysis was conducted using Fisher's exact test. The overall survival and cumulative patency rates were assessed using the Kaplan–Meier method.

Results

The 1‐year cumulative survival rate was 37.8% after stent placement. The 3‐month, 6‐month, and 1‐year cumulative patency rates after stenting were 93.6%, 84.2%, and 75.8%, respectively. The major adverse events included stent migration (6.2%), stent occlusion (9.9%), and perforation (2.5%). Chemotherapy was administered in 26 cases (32.1%) after stenting, and bevacizumab was administered in five cases. However, no cases of perforation occurred following bevacizumab administration.

Conclusions

Our results suggest that very low AF stents are safe and effective. Therefore, they may be a suitable option for applications, such as palliation. (UMIN 000011304)

Schlagwörter

Stichwörter der Autor:innen

anti‐VEGF antibodyaxial forcemalignant colorectal obstructionperforationself‐expandable metallic stent

Autor:innen und Institutionen

  • Department of Gastroenterology Saiseikai Yokohamashi-Nanbu Hospital Kanagawa Japan.
  • Department of Hepato-Biliary-Pancreatic Medicine Cancer Institute Hospital of Japanese Foundation for Cancer Research Tokyo Japan.
  • Department of Endoscopy and Endoscopic Surgery Graduate School of Medicine The University of Tokyo Tokyo Japan.
  • Department of Gastroenterology Graduate School of Medicine Juntendo University Tokyo Japan.
  • Department of Gastroenterology Japanese Red Cross Aichi Medical Center Nagoya Daini Hospital Aichi Japan.
  • Department of Surgery Toho University Ohashi Medical Center Tokyo Japan.

ORCID-Profile: Rika Kyo, Hiroyuki Isayama, Rintaro Moroi

Zitieren

APA

Kyo, R., Sasaki, T., Yoshida, S., Isayama, H., Yamada, T., Enomoto, T., Sumida, Y., Kuwai, T., Tomita, M., Matsuzawa, T., Moroi, R., Shiratori, T., & Saida, Y. (2026). Long‐term results of palliative placement of very low‐axial force self‐expandable metallic stents for malignant colorectal obstruction. DEN Open, 6(1). https://doi.org/10.1002/deo2.70126

Vancouver

Kyo R, Sasaki T, Yoshida S, Isayama H, Yamada T, Enomoto T, et al. Long‐term results of palliative placement of very low‐axial force self‐expandable metallic stents for malignant colorectal obstruction. DEN Open. 2026;6(1). doi:10.1002/deo2.70126

BibTeX
@article{Kyo2026,
  author = {Kyo, Rika and Sasaki, Takashi and Yoshida, Shuntaro and Isayama, Hiroyuki and Yamada, Tomonori and Enomoto, Toshiyuki and Sumida, Yorinobu and Kuwai, Toshio and Tomita, Masafumi and Matsuzawa, Takeaki and Moroi, Rintaro and Shiratori, Toshiyasu and Saida, Yoshihisa},
  title = {Long‐term results of palliative placement of very low‐axial force self‐expandable metallic stents for malignant colorectal obstruction},
  journal = {DEN Open},
  year = {2026},
  volume = {6},
  number = {1},
  doi = {10.1002/deo2.70126}
}
Kostenlos starten →