Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction
Clinical Endoscopy · 30.11.2023 · 56 (6) · 802-811
DOI: 10.5946/ce.2022.211 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Endoscopy, erschienen am 30.11.2023. Verfasst von Taro Shibuki und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital East, Chiba, Japan. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan.
Methods
Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated.
Results
PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309).Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital East, Chiba, Japan.
- Department of Gastroenterology, Jichi Medical University Saitama Medical Center, Saitama, Japan.
- Department of Gastroenterology, Dokkyo Medical University Saitama Medical Center, Saitama, Japan.
- Department of Gastroenterology, Toyooka Hospital, Hyogo, Japan.
- Department of Gastroenterology, National Organization Disaster Medical Center, Tokyo, Japan.
- Department of Gastroenterology, Fujigaoka Hospital, Showa University, Kanagawa, Japan.
Zitieren
APA
Shibuki, T., Okumura, K., Sekine, M., Kobori, I., Miyagaki, A., Sasaki, Y., Takano, Y., & Hashimoto, Y. (2023). Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction. Clinical Endoscopy, 56(6), 802-811. https://doi.org/10.5946/ce.2022.211
Vancouver
Shibuki T, Okumura K, Sekine M, Kobori I, Miyagaki A, Sasaki Y, et al. Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction. Clinical Endoscopy. 2023;56(6):802-811. doi:10.5946/ce.2022.211
BibTeX
@article{Shibuki2023,
author = {Shibuki, Taro and Okumura, Kei and Sekine, Masanari and Kobori, Ikuhiro and Miyagaki, Aki and Sasaki, Yoshihiro and Takano, Yuichi and Hashimoto, Yusuke},
title = {Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction},
journal = {Clinical Endoscopy},
year = {2023},
volume = {56},
number = {6},
pages = {802--811},
doi = {10.5946/ce.2022.211}
}
EUVIMED