EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Insufficient endobronchial ultrasound‐guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens

Antti Vuorisalo, Heini Huhtala, Timo Paavonen, Ivana Kholová

Diagnostic Cytopathology · 2024

DOI: 10.1002/dc.25284 ↗

At a glance

Journal article in Diagnostic Cytopathology, 2024. Written by Antti Vuorisalo and 3 co-authors. Institution: Pathology, Fimlab Laboratories, Tampere, Finland. Major MEDLINE topics: Lung Neoplasms, Carcinoma, Non-Small-Cell Lung. Cited 7 times so far (Crossref); 42 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Tampereen Tuberkuloosisäätiö, Pirkanmaan Sairaanhoitopiiri, Väinö ja Laina Kiven Säätiö.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The classification terminology systems for pulmonary cytology specimens have recently emerged. Inadequate samples, classified as "nondiagnostic," raise challenges in determining the threshold of cell numbers and the risk of malignancy (ROM).

Methods

The study retrospectively reviewed 248 endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) samples: 46 insufficient samples, 60 low cellularity samples, and 142 adequate samples. Characteristics as cellularity, number of benign and malignant cells, and background features were assessed. Receiver operating characteristic curve analysis was performed to establish cell sufficiency thresholds for the diagnosis.

Results

Out of the 248 samples analyzed, 108 were classified as benign, 94 as malignant, and 46 as insufficient. The study found that the cellularity thresholds for diagnosis in cell blocks and cytological samples were ≥50 cells and ≥100 cells, respectively. The thresholds for tumor cell counts were ≥1 − 10 cells for both types of cells, respectively. Considerably, some low cellularity samples were initially classified as insufficient despite meeting the diagnostic thresholds upon revision. The ROM varied across sample categories, with insufficient samples having a ROM of 10.9%, benign samples 15.7%, suspicious samples 92.0%, and malignant samples 100%.

Conclusion

Insufficient EBUS‐TBNA samples raise challenges in diagnosis and management. This study identified the root cause of insufficient samples, including factors related to humans, diagnostic methods, sampling, and laboratory processing. By understanding the root causes, diagnostic recommendations can be developed to improve the diagnostic process. The findings emphasize the importance of standardized classification and terminology systems for clear communication among healthcare professionals and institutions, ultimately improving patient care and enabling quality assurance measures.

Subjects

MeSH terms (MEDLINE)

Lung NeoplasmsCarcinoma, Non-Small-Cell LungHumansRetrospective StudiesEndoscopic Ultrasound-Guided Fine Needle AspirationLungBronchoscopyLymph Nodes

Author keywords

EBUS‐TBNAadequacycell blockinsufficientlungpulmonary cytology

Authors and institutions

  • Pathology, Fimlab Laboratories, Tampere, Finland.
  • Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.

Funding

  • Tampereen Tuberkuloosisäätiö
  • Pirkanmaan Sairaanhoitopiiri
  • Väinö ja Laina Kiven Säätiö

Cite

APA

Vuorisalo, A., Huhtala, H., Paavonen, T., & Kholová, I. (2024). Insufficient endobronchial ultrasound‐guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens. Diagnostic Cytopathology. https://doi.org/10.1002/dc.25284

Vancouver

Vuorisalo A, Huhtala H, Paavonen T, Kholová I. Insufficient endobronchial ultrasound‐guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens. Diagnostic Cytopathology. 2024. doi:10.1002/dc.25284

BibTeX
@article{Vuorisalo2024,
  author = {Vuorisalo, Antti and Huhtala, Heini and Paavonen, Timo and Kholová, Ivana},
  title = {Insufficient endobronchial ultrasound‐guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens},
  journal = {Diagnostic Cytopathology},
  year = {2024},
  doi = {10.1002/dc.25284}
}
Start for free →