Traceable Refractive Index Measurements of Liquids to Standardize Extracellular Vesicle Flow Cytometry
Cytometry Part A · 2026-02 · 109 (2) · 115-123
DOI: 10.1002/cytoa.70015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cytometry Part A, online erschienen am 23.02.2026. Verfasst von Martine Kuiper und 4 weiteren Autor:innen. Beteiligte Einrichtung: VSL, National Metrology Institute, Delft, the Netherlands. Hauptthemen laut MEDLINE: Flow Cytometry, Refractometry, Extracellular Vesicles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Association of National Metrology Institutes, Nederlandse Organisatie voor Wetenschappelijk Onderzoek.
Abstract (Originalsprache)
Extracellular vesicles (EVs) are potential disease biomarkers released by cells into body fluids. Flow cytometers measure EV concentrations within their size detection range. These size ranges can be quantified by relating the arbitrary units of measured light scattering signals to the optical diameter of EVs with Mie theory. However, Mie theory requires input parameters, including the refractive index (RI) of the suspension liquid surrounding the measured particles, which is not accurately known. Here we measure traceable RIs of suspension liquids, including Dulbecco's phosphate buffered saline (DPBS) and human blood plasma dilutions with an uncertainty of for relevant wavelengths between 405 and 644 nm. We show that differences between traceably measured and currently used RIs for suspension liquids lead to differences in applied optical diameter gates and reported EV concentrations. The currently assumed RI of DPBS in Rosetta Calibration leads to a difference of 9% to 35% between reported and actual EV concentrations in diluted plasma, depending on the lower detection limit of the flow cytometer. A traceably measured RI of the suspension liquid should be used to calibrate light scattering signals with Mie theory to improve accuracy of optical diameter and concentration measurements by EV flow cytometry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- VSL, National Metrology Institute, Delft, the Netherlands.
- Laboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
- Amsterdam Vesicle Center, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
- Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
- Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
ORCID-Profile: Martine Kuiper, Rienk Nieuwland, Ton G van Leeuwen, Edwin van der Pol
Förderung
- European Association of National Metrology Institutes
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Zitieren
APA
Kuiper, M., Koops, R., Nieuwland, R., van Leeuwen, T. G., & van der Pol, E. (2026). Traceable Refractive Index Measurements of Liquids to Standardize Extracellular Vesicle Flow Cytometry. Cytometry Part A, 109(2), 115-123. https://doi.org/10.1002/cytoa.70015
Vancouver
Kuiper M, Koops R, Nieuwland R, van Leeuwen TG, van der Pol E. Traceable Refractive Index Measurements of Liquids to Standardize Extracellular Vesicle Flow Cytometry. Cytometry Part A. 2026;109(2):115-123. doi:10.1002/cytoa.70015
BibTeX
@article{Kuiper2026,
author = {Kuiper, Martine and Koops, Richard and Nieuwland, Rienk and van Leeuwen, Ton G and van der Pol, Edwin},
title = {Traceable Refractive Index Measurements of Liquids to Standardize Extracellular Vesicle Flow Cytometry},
journal = {Cytometry Part A},