Uncertainty Quantification in Flow Cytometry Using a Cell Sorter
Cytometry Part A · 2025
DOI: 10.1002/cyto.a.24925 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cytometry Part A, 2025. Verfasst von Amudhan Krishnaswamy-Usha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Applied and Computational Mathematics Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA. Hauptthemen laut MEDLINE: Flow Cytometry, Cell Separation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: NIST DOC, National Institute of Standards and Technology.
Abstract (Originalsprache)
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Applied and Computational Mathematics Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
- Chakra Consulting Inc, Clarksburg, Maryland, USA.
- Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
ORCID-Profile: Amudhan Krishnaswamy-Usha
Förderung
- NIST DOC
- National Institute of Standards and Technology
Zitieren
APA
Krishnaswamy-Usha, A., Cooksey, G. A., & Patrone, P. N. (2025). Uncertainty Quantification in Flow Cytometry Using a Cell Sorter. Cytometry Part A. https://doi.org/10.1002/cyto.a.24925
Vancouver
Krishnaswamy-Usha A, Cooksey GA, Patrone PN. Uncertainty Quantification in Flow Cytometry Using a Cell Sorter. Cytometry Part A. 2025. doi:10.1002/cyto.a.24925
BibTeX
@article{KrishnaswamyUsha2025,
author = {Krishnaswamy-Usha, Amudhan and Cooksey, Gregory A and Patrone, Paul N},
title = {Uncertainty Quantification in Flow Cytometry Using a Cell Sorter},
journal = {Cytometry Part A},
year = {2025},
doi = {10.1002/cyto.a.24925}
}
EUVIMED