Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, 2025. Verfasst von Prajakta Bedekar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Applied and Computational Mathematics Division, Information Technology Laboratory, National Institute of Standards and Technology, Gaithersburg, Mary…. Hauptthemen laut MEDLINE: Flow Cytometry. Die Arbeit nennt 20 Literaturangaben. Gefördert von: NIST DOC, National Institute of Standards and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flow cytometry measurements are widely used in diagnostics and medical decision making. Incomplete understanding of sources of measurement uncertainty can make it difficult to distinguish autofluorescence and background sources from signals of interest. Moreover, established methods for modeling uncertainty overlook the fact that the apparent distribution of measurements is a convolution of the inherent population variability (e.g., associated with calibration beads or cells) and instrument‐induced effects. Such issues make it difficult, for example, to identify signals from small objects such as extracellular vesicles. To overcome such limitations, we formulate an explicit probabilistic measurement model that accounts for volume and labeling variation, background signals, and fluorescence shot noise. Using raw data from routine per‐event calibration measurements, we use this model to separate the aforementioned sources of uncertainty and demonstrate how such information can be used to facilitate decision making and instrument characterization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryCalibrationUncertaintyHumansMicrospheresFluorescence

Stichwörter der Autor:innen

calibration beadsinstrument uncertaintiesmathematical methodsuncertainty quantification

Autor:innen und Institutionen

  • Applied and Computational Mathematics Division, Information Technology Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
  • Department of Applied Mathematics and Statistics, Johns Hopkins University, Baltimore, Maryland, USA.
  • Microsystems and Nanotechnology Division, Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.

ORCID-Profile: Prajakta Bedekar, Gregory A Cooksey, Anthony J Kearsley, Paul N Patrone

Förderung

  • NIST DOC
  • National Institute of Standards and Technology

Zitieren

APA

Bedekar, P., Catterton, M. A., DiSalvo, M., Cooksey, G. A., Kearsley, A. J., & Patrone, P. N. (2025). Per‐Event Uncertainty Quantification for Flow Cytometry Using Calibration Beads. Cytometry Part A. https://doi.org/10.1002/cyto.a.24954

Vancouver

Bedekar P, Catterton MA, DiSalvo M, Cooksey GA, Kearsley AJ, Patrone PN. Per‐Event Uncertainty Quantification for Flow Cytometry Using Calibration Beads. Cytometry Part A. 2025. doi:10.1002/cyto.a.24954

BibTeX
@article{Bedekar2025,
  author = {Bedekar, Prajakta and Catterton, Megan A and DiSalvo, Matthew and Cooksey, Gregory A and Kearsley, Anthony J and Patrone, Paul N},
  title = {Per‐Event Uncertainty Quantification for Flow Cytometry Using Calibration Beads},
  journal = {Cytometry Part A},
  year = {2025},
  doi = {10.1002/cyto.a.24954}
}
Kostenlos starten →