EUVIMEDEUVIMED entdecken
Crossref

Combinatorial antibody titrations for high‐parameter flow cytometry

Olivia K Burn, Florian Mair iD, Laura Ferrer-Font iD

Cytometry Part A · 2024-05 · 105 (5) · 388-393

DOI: 10.1002/cyto.a.24828 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, online erschienen am 06.02.2024. Verfasst von Olivia K Burn und 2 weiteren Autor:innen. Beteiligte Einrichtung: Malaghan Institute of Medical Research, Wellington, New Zealand. Hauptthemen laut MEDLINE: Flow Cytometry, Fluorescent Dyes, Antibodies. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 9 Literaturangaben. Gefördert von: WJ & AF Morris Cancer Research Foundation Trust, Dines Family Trust, Cancer Society of New Zealand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The objective of titrating fluorochrome‐labeled antibodies is to identify the optimal concentration for a given marker‐fluorochrome pair that results in the best possible separation between the positive and negative cell populations, while minimizing the background within the negative population. Best practices in flow cytometry dictate that each new lot of antibody should be titrated on the sample of interest. However, many researchers routinely use large (30+) color panels due to recent technical advancements in fluorescence‐based cytometry instrumentation which quickly leads to an unmanageable number of individual titrations. In this technical note, we provide evidence that antibodies can be effectively titrated in groups rather than individually, resulting in considerable time and cost savings. This approach streamlines the process, without compromising data quality, thereby enhancing the efficiency of setting up high‐parameter cytometry experiments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryFluorescent DyesAntibodiesHumans

Stichwörter der Autor:innen

dilutionshigh‐dimensional flow cytometryoptimal concentrationtiterstitrations

Substanzen

Fluorescent DyesAntibodies

Autor:innen und Institutionen

  • Malaghan Institute of Medical Research, Wellington, New Zealand.
  • Flow Cytometry Core Facility, Institute of Molecular Health Sciences, ETH Zurich, Zurich, Switzerland.
  • Hugh Green Cytometry Centre, Malaghan Institute of Medical Research, Wellington, New Zealand.

ORCID-Profile: Florian Mair, Laura Ferrer-Font

Förderung

  • WJ & AF Morris Cancer Research Foundation Trust
  • Dines Family Trust
  • Cancer Society of New Zealand

Zitieren

APA

Burn, O. K., Mair, F., & Ferrer-Font, L. (2024). Combinatorial antibody titrations for high‐parameter flow cytometry. Cytometry Part A, 105(5), 388-393. https://doi.org/10.1002/cyto.a.24828

Vancouver

Burn OK, Mair F, Ferrer-Font L. Combinatorial antibody titrations for high‐parameter flow cytometry. Cytometry Part A. 2024;105(5):388-393. doi:10.1002/cyto.a.24828

BibTeX
@article{Burn2024,
  author = {Burn, Olivia K and Mair, Florian and Ferrer-Font, Laura},
  title = {Combinatorial antibody titrations for high‐parameter flow cytometry},
  journal = {Cytometry Part A},
  year = {2024},
  volume = {105},
  number = {5},
  pages = {388--393},
  doi = {10.1002/cyto.a.24828}
}
Kostenlos starten →