Automated antibody dispensing to improve high‐parameter flow cytometry throughput and analysis
Cytometry Part A · 2024
DOI: 10.1002/cyto.a.24835 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cytometry Part A, 2024. Verfasst von Victor Bosteels und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine and Pediatrics, Ghent University, Ghent, Belgium. Hauptthemen laut MEDLINE: Flow Cytometry, Antibodies, Fluorescent Dyes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: ERC, FWO Program, FWO EOS.
Abstract (Originalsprache)
Over the past decade, the flow cytometry field has witnessed significant advancements in the number of fluorochromes that can be detected. This enables researchers to analyze more than 40 markers simultaneously on thousands of cells per second. However, with this increased complexity and multiplicity of markers, the manual dispensing of antibodies for flow cytometry experiments has become laborious, time‐consuming, and prone to errors. An automated antibody dispensing system could provide a potential solution by enhancing the efficiency, and by improving data quality by faithfully dispensing the fluorochrome‐conjugated antibodies and by enabling the easy addition of extra controls. In this study, a comprehensive comparison of different liquid handlers for dispensing fluorochrome‐labeled antibodies was conducted for the preparation of flow cytometry stainings. The evaluation focused on key criteria including dispensing time, dead volume, and reliability of dispensing. After benchmarking, the I.DOT, a non‐contact liquid handler, was selected and optimized in more detail. In the end, the I.DOT was able to prepare a 25‐marker panel in 20 min, including the full stain, all FMOs and all single stain controls for cells and beads. Having all these controls improved the validation of the panel, visualization, and analysis of the data. Thus, automated antibody dispensing by dispensers such as the I.DOT reduces time and errors, enhances data quality, and can be easily integrated in an automated workflow to prepare samples for flow cytometry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Internal Medicine and Pediatrics, Ghent University, Ghent, Belgium.
- Laboratory for ER Stress and Inflammation, VIB Center for Inflammation Research, Ghent, Belgium.
- Department of Biomedical Molecular Biology, Ghent University, Ghent, Belgium.
- VIB Flow Core, VIB Center for Inflammation Research, Ghent, Belgium.
- VIB Screening Core, VIB, Ghent, Belgium.
- Center for Bioassay Development and Screening, Ghent University, Ghent, Belgium.
ORCID-Profile: Victor Bosteels, Gert Van Isterdael
Förderung
- ERC
- FWO Program
- FWO EOS
- FWO PhD
- H2020 European Research Council
Zitieren
APA
Bosteels, V., Van Duyse, J., Ruyssinck, E., Van der Borght, K., Nguyen, L., Gavel, J., Janssens, S., & Van Isterdael, G. (2024). Automated antibody dispensing to improve high‐parameter flow cytometry throughput and analysis. Cytometry Part A. https://doi.org/10.1002/cyto.a.24835
Vancouver
Bosteels V, Van Duyse J, Ruyssinck E, Van der Borght K, Nguyen L, Gavel J, et al. Automated antibody dispensing to improve high‐parameter flow cytometry throughput and analysis. Cytometry Part A. 2024. doi:10.1002/cyto.a.24835
BibTeX
@article{Bosteels2024,
author = {Bosteels, Victor and Van Duyse, Julie and Ruyssinck, Elien and Van der Borght, Katrien and Nguyen, Long and Gavel, Jannes and Janssens, Sophie and Van Isterdael, Gert},
title = {Automated antibody dispensing to improve high‐parameter flow cytometry throughput and analysis},
journal = {Cytometry Part A},
year = {2024},
doi = {10.1002/cyto.a.24835}
}
EUVIMED