EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis

W Khalaily, S Bhowmick iD, Y Tsur iD

ChemSusChem · 2025-02 · 18 (3)

DOI: 10.1002/cssc.202401488 ↗

At a glance

Journal article in ChemSusChem, published online on 2024-10-28. Written by W Khalaily and 2 co-authors. Institution: The Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa, Israel. Cited 6 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Ministry of Energy, Israel, Israeli National Institute for Energy Storage, Planning and Budgeting Committee of the Council for Higher Education of Israel.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The effect of NO 2 , an air pollutant, on the durability of polymer electrolyte membrane fuel cells (PEMFCs) and the affected electrochemical processes in the PEMFC following the contamination were investigated. In‐situ Electrochemical Impedance Spectroscopy (EIS) measurements were conducted on PEMFCs under different operating conditions of temperature and relative humidity (RH). NO 2 was introduced to the cathode inlet flow. Analyses of the EIS measurements were performed using a genetic algorithm called ISGP (Impedance Spectroscopy by Genetic Programming) to obtain the distribution function of relaxation times (DFRT, a.k.a. DRT) models. Utilizing ISGP enabled us to differentiate the various phenomena in PEMFC and study how they are affected by NO 2 contamination. Moreover, the experiments demonstrate the effectiveness of the mitigation method to flush the PEMFC and regenerate its performance after being contaminated, particularly at low operating temperatures. Energy‐dispersive X‐ray spectroscopy (EDS) technique is performed on the contaminated PEMFC to detect the presence of any nitrogen components in the FC′s gas diffusion layer and the catalyst layer post the mitigation step. Cyclic Voltammetry is also performed on the contaminated cell to determine the effect of the contamination on the electrochemically active surface area of the cathode by evaluating the double‐layer capacitance.

Subjects

Author keywords

Distribution function of relaxation timesElectrochemical impedance spectroscopyISGPOxygen reduction reactionPolymer electrolyte membrane fuel cells

Authors and institutions

  • The Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
  • The Stephen and Nancy Grand Technion Energy Program (GTEP), Technion.

ORCID profiles: S Bhowmick, Y Tsur

Funding

  • Ministry of Energy, Israel
  • Israeli National Institute for Energy Storage
  • Planning and Budgeting Committee of the Council for Higher Education of Israel
  • Israel Science Foundation

Cite

APA

Khalaily, W., Bhowmick, S., & Tsur, Y. (2025). Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis. ChemSusChem, 18(3). https://doi.org/10.1002/cssc.202401488

Vancouver

Khalaily W, Bhowmick S, Tsur Y. Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis. ChemSusChem. 2025;18(3). doi:10.1002/cssc.202401488

BibTeX
@article{Khalaily2025,
  author = {Khalaily, W and Bhowmick, S and Tsur, Y},
  title = {Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis},
  journal = {ChemSusChem},
  year = {2025},
  volume = {18},
  number = {3},
  doi = {10.1002/cssc.202401488}
}
Start for free →