EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis

W Khalaily, S Bhowmick iD, Y Tsur iD

ChemSusChem · 2025-02 · 18 (3)

DOI: 10.1002/cssc.202401488 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemSusChem, online erschienen am 28.10.2024. Verfasst von W Khalaily und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa, Israel. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Energy, Israel, Israeli National Institute for Energy Storage, Planning and Budgeting Committee of the Council for Higher Education of Israel.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effect of NO 2 , an air pollutant, on the durability of polymer electrolyte membrane fuel cells (PEMFCs) and the affected electrochemical processes in the PEMFC following the contamination were investigated. In‐situ Electrochemical Impedance Spectroscopy (EIS) measurements were conducted on PEMFCs under different operating conditions of temperature and relative humidity (RH). NO 2 was introduced to the cathode inlet flow. Analyses of the EIS measurements were performed using a genetic algorithm called ISGP (Impedance Spectroscopy by Genetic Programming) to obtain the distribution function of relaxation times (DFRT, a.k.a. DRT) models. Utilizing ISGP enabled us to differentiate the various phenomena in PEMFC and study how they are affected by NO 2 contamination. Moreover, the experiments demonstrate the effectiveness of the mitigation method to flush the PEMFC and regenerate its performance after being contaminated, particularly at low operating temperatures. Energy‐dispersive X‐ray spectroscopy (EDS) technique is performed on the contaminated PEMFC to detect the presence of any nitrogen components in the FC′s gas diffusion layer and the catalyst layer post the mitigation step. Cyclic Voltammetry is also performed on the contaminated cell to determine the effect of the contamination on the electrochemically active surface area of the cathode by evaluating the double‐layer capacitance.

Schlagwörter

Stichwörter der Autor:innen

Distribution function of relaxation timesElectrochemical impedance spectroscopyISGPOxygen reduction reactionPolymer electrolyte membrane fuel cells

Autor:innen und Institutionen

  • The Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
  • The Stephen and Nancy Grand Technion Energy Program (GTEP), Technion.

ORCID-Profile: S Bhowmick, Y Tsur

Förderung

  • Ministry of Energy, Israel
  • Israeli National Institute for Energy Storage
  • Planning and Budgeting Committee of the Council for Higher Education of Israel
  • Israel Science Foundation

Zitieren

APA

Khalaily, W., Bhowmick, S., & Tsur, Y. (2025). Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis. ChemSusChem, 18(3). https://doi.org/10.1002/cssc.202401488

Vancouver

Khalaily W, Bhowmick S, Tsur Y. Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis. ChemSusChem. 2025;18(3). doi:10.1002/cssc.202401488

BibTeX
@article{Khalaily2025,
  author = {Khalaily, W and Bhowmick, S and Tsur, Y},
  title = {Studying the Effect of Operating Conditions and NO 2 Cathode Contamination on PEM Fuel Cells Using Distribution Function of Relaxation Times Analysis},
  journal = {ChemSusChem},
  year = {2025},
  volume = {18},
  number = {3},
  doi = {10.1002/cssc.202401488}
}
Kostenlos starten →