Effect of Bonding Height on Force‐Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study
Clinical and Experimental Dental Research · 2026-06 · 12 (3)
DOI: 10.1002/cre2.70396 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 28.06.2026. Verfasst von Francesca Thaden und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Orthodontic Retainers, Dental Bonding, Orthodontic Appliance Design. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To investigate the effect of different bonding heights on force‐moment generation in orthodontic fixed lingual retainers under loading in a biomechanical setup. Materials and Methods Three commercially available lingual retainers were evaluated: two conventionally fabricated stainless‐steel retainers (R1, R2) and one CAD/CAM‐manufactured nickel‐titanium retainer (R3). Using a biomechanical test setup, vertical forces and labiolingual moments were recorded and applied in three dimensions in response to a standardized vertical displacement of 0.3 mm. The effect of three standardized bonding heights (incisal, middle, and gingival thirds of the clinical crown) was assessed.
Results
Both forces and moments increased with vertical loading. Statistically significant differences were observed among retainer materials, whereas bonding height did not significantly affect the outcomes. At 0.3 mm vertical displacement, the lowest force and moment were recorded for R1 bonded incisally (0.59 ± 0.37 N; 3.48 ± 0.37 Nmm), and the highest for R3 at mid‐crown bonding height (1.40 ± 0.13 N; 8.70 ± 1.19 Nmm).
Conclusions
Retainer type was found to have a greater influence on force and moment development than bonding height. Multistranded stainless‐steel retainers may be more susceptible to deformation under occlusal loading. Further studies are required to determine the clinical relevance of bonding height in fixed lingual retainers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Zitieren
APA
Thaden, F., Hötzel, L., Dotzer, B., Mertmann, M., Wichelhaus, A., & Sabbagh, H. (2026). Effect of Bonding Height on Force‐Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study. Clinical and Experimental Dental Research, 12(3). https://doi.org/10.1002/cre2.70396
Vancouver
Thaden F, Hötzel L, Dotzer B, Mertmann M, Wichelhaus A, Sabbagh H. Effect of Bonding Height on Force‐Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study. Clinical and Experimental Dental Research. 2026;12(3). doi:10.1002/cre2.70396
BibTeX
@article{Thaden2026,
author = {Thaden, Francesca and Hötzel, Linus and Dotzer, Benedikt and Mertmann, Matthias and Wichelhaus, Andrea and Sabbagh, Hisham},
title = {Effect of Bonding Height on Force‐Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study},
journal = {Clinical and Experimental Dental Research},
year = {2026},
volume = {12},
number = {3},
doi = {10.1002/cre2.70396}
}
EUVIMED