EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A Comparative Study on the Fracture Resistance of CAD/CAM–Fabricated Single‐Piece Post‐Crowns

Ali Erdem, Mehmet Selim Bilgin, Ibrahim Ersoy, Erhan Dilber, Ebru Nur Işık, Tan Fırat Eyüboğlu, Mutlu Özcan iD

Clinical and Experimental Dental Research · 2025

DOI: 10.1002/cre2.70247 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical and Experimental Dental Research, 2025. Verfasst von Ali Erdem und 6 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, İzmir, Türkiye. Hauptthemen laut MEDLINE: Computer-Aided Design, Post and Core Technique, Crowns, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this study..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Recently, CAD/CAM materials have become popular in dental clinics; however, information about their fracture resistance as post‐crowns remains limited. This study compared the initial fracture resistance of potential single‐piece post‐crown materials made with CAD/CAM milling to sound teeth. Materials and Methods Fifty freshly extracted, non‐carious human central incisor teeth underwent endodontic treatment. The roots were then randomly divided into five groups based on the post systems: the control group included teeth filled only with gutta‐percha. Monoblock post‐crowns were made using four different systems for the other groups: LDS (IPS e.max CAD®, lithium disilicate glass‐ceramic), YTZP (inCoris ZI®, Yttrium tetragonal zirconia polycrystal), RNC (Lava Ultimate®, resin‐based nanoceramic), and PICN (VITA Enamic®, polymer‐infiltrated ceramic network). The post‐crowns were cemented with resin cement and tested with a universal testing machine at a crosshead speed of 1.0 mm/min. Data analysis used one‐way ANOVA and multiple comparison post‐hoc Tukey tests ( α = 0.05).

Results

Significant differences were found between the groups ( p < 0.001). The control group exhibited the highest fracture resistance (749.25 ± 225.02 N). YTZP showed similar resistance to the control ( p = 0.99) and LDS (447.28 ± 168.72 N, p = 0.081), but was significantly higher than RNC (343.79 ± 157.08 N, p = 0.0051) and PICN (348.78 ± 157.44 N, p = 0.0059). LDS, RNC, and PICN did not differ significantly. YTZP experienced more non‐repairable fractures (5/10), while PICN predominantly failed in a repairable manner (9/10).

Conclusions

All CAD/CAM post‐crowns exceeded functional loads for the anterior region. YTZP and LDS demonstrated greater strength, whereas PICN and RNC, despite being weaker, favored repairable failures—highlighting the importance of balancing strength and clinical manageability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignPost and Core TechniqueCrownsDental Prosthesis DesignTooth FracturesDental Restoration FailureHumansDental Stress AnalysisCeramicsZirconiumMaterials TestingDental PorcelainIncisorResin CementsDental Materials

Stichwörter der Autor:innen

CAD/CAMYttrium tetragonal zirconia polycrystaldental materialsfracture resistancepolymer‐infiltrated ceramic networkpost‐crown

Substanzen

ZirconiumDental Porcelainlithia disilicateGlass ceramicsResin CementsDental MaterialsVITA Enamic

Autor:innen und Institutionen

  • Private Practice, İzmir, Türkiye.
  • Faculty of Dentistry, Department of Prosthodontics, Alanya Alaaddin Keykubat University, Alanya, Türkiye.
  • Private Practice, İstanbul, Türkiye.
  • Department of Endodontics, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Türkiye.
  • Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.

ORCID-Profile: Mutlu Özcan

Förderung

  • The authors received no specific funding for this study.

Zitieren

APA

Erdem, A., Bilgin, M. S., Ersoy, I., Dilber, E., Işık, E. N., Eyüboğlu, T. F., & Özcan, M. (2025). A Comparative Study on the Fracture Resistance of CAD/CAM–Fabricated Single‐Piece Post‐Crowns. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70247

Vancouver

Erdem A, Bilgin MS, Ersoy I, Dilber E, Işık EN, Eyüboğlu TF, et al. A Comparative Study on the Fracture Resistance of CAD/CAM–Fabricated Single‐Piece Post‐Crowns. Clinical and Experimental Dental Research. 2025. doi:10.1002/cre2.70247

BibTeX
@article{Erdem2025,
  author = {Erdem, Ali and Bilgin, Mehmet Selim and Ersoy, Ibrahim and Dilber, Erhan and Işık, Ebru Nur and Eyüboğlu, Tan Fırat and Özcan, Mutlu},
  title = {A Comparative Study on the Fracture Resistance of CAD/CAM–Fabricated Single‐Piece Post‐Crowns},
  journal = {Clinical and Experimental Dental Research},
  year = {2025},
  doi = {10.1002/cre2.70247}
}
Kostenlos starten →