EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology

Artur F M Farinha, Soraia R M R Silva, Alexandre C P M Alves, Luís M N B F Santos, Oleksandr Bondarchuk, José C S Costa iD

ChemPhysChem · 2026-04-14 · 27 (7)

DOI: 10.1002/cphc.70349 ↗

At a glance

Journal article in ChemPhysChem, published online on 2026-04-10. Written by Artur F M Farinha and 5 co-authors. Institution: CIQUP/Institute of Molecular Sciences (IMS), Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Porto, Portugal. 55 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The understanding of the sensitivity of quartz crystal microbalances (QCMs) to the mass of ionic liquid (IL) films is essential to rationalize their deposition behavior and the limits of reliable mass measurement. Herein, [C 2 C 1 im][OTf] films were vapor‐deposited on Au‐coated QCMs over a wide mass range (0.6–55 µg cm −2 ) and characterized using QCM, scanning electron microscopy (SEM), atomic force microscopy (AFM), and X‐ray photoelectron spectroscopy (XPS). At low coverages, QCM frequency shifts follow a linear trend, consistent with rigid mass coupling, while deviations from linearity and eventual sensor saturation occur at higher mass loadings. SEM and AFM show that the IL initially fills confined surface features, forming isolated patches, and progressively evolves into extended, quasi‐continuous domains. XPS indicates that low‐mass films display surface compositions deviating from stoichiometry, whereas high‐mass films (55 µg cm −2 ) show cation enrichment at the outermost surface. These findings demonstrate that QCM failure is linked to the transition from a confined, interface‐dominated regime to a microdroplet‐type, bulk‐like film, where viscoelastic IL patches decouple from the oscillating crystal. By correlating film morphology, surface composition, and QCM response, this study provides a comprehensive framework to interpret the limitations of QCM mass detection of IL films under vacuum.

Subjects

Author keywords

film morphology and structureionic liquidsnanoscale confinementquartz crystal microbalance (QCM)vapor deposition

Authors and institutions

  • CIQUP/Institute of Molecular Sciences (IMS), Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Porto, Portugal.
  • International Iberian Nanotechnology Laboratory, Braga, Portugal.
  • SPIN-Lab Centre for Microscopic Research on Matter, University of Silesia in Katowice, Chorzów, Poland.
  • Institute of Chemistry, University of Silesia in Katowice, Katowice, Poland.

ORCID profiles: José C S Costa

Cite

APA

Farinha, A. F. M., Silva, S. R. M. R., Alves, A. C. P. M., Santos, L. M. N. B. F., Bondarchuk, O., & Costa, J. C. S. (2026). Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology. ChemPhysChem, 27(7). https://doi.org/10.1002/cphc.70349

Vancouver

Farinha AFM, Silva SRMR, Alves ACPM, Santos LMNBF, Bondarchuk O, Costa JCS. Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology. ChemPhysChem. 2026;27(7). doi:10.1002/cphc.70349

BibTeX
@article{Farinha2026,
  author = {Farinha, Artur F M and Silva, Soraia R M R and Alves, Alexandre C P M and Santos, Luís M N B F and Bondarchuk, Oleksandr and Costa, José C S},
  title = {Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology},
  journal = {ChemPhysChem},
  year = {2026},
  volume = {27},
  number = {7},
  doi = {10.1002/cphc.70349}
}
Start for free →