Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology
ChemPhysChem · 14.04.2026 · 27 (7)
DOI: 10.1002/cphc.70349 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemPhysChem, online erschienen am 10.04.2026. Verfasst von Artur F M Farinha und 5 weiteren Autor:innen. Beteiligte Einrichtung: CIQUP/Institute of Molecular Sciences (IMS), Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Porto, Portugal. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The understanding of the sensitivity of quartz crystal microbalances (QCMs) to the mass of ionic liquid (IL) films is essential to rationalize their deposition behavior and the limits of reliable mass measurement. Herein, [C 2 C 1 im][OTf] films were vapor‐deposited on Au‐coated QCMs over a wide mass range (0.6–55 µg cm −2 ) and characterized using QCM, scanning electron microscopy (SEM), atomic force microscopy (AFM), and X‐ray photoelectron spectroscopy (XPS). At low coverages, QCM frequency shifts follow a linear trend, consistent with rigid mass coupling, while deviations from linearity and eventual sensor saturation occur at higher mass loadings. SEM and AFM show that the IL initially fills confined surface features, forming isolated patches, and progressively evolves into extended, quasi‐continuous domains. XPS indicates that low‐mass films display surface compositions deviating from stoichiometry, whereas high‐mass films (55 µg cm −2 ) show cation enrichment at the outermost surface. These findings demonstrate that QCM failure is linked to the transition from a confined, interface‐dominated regime to a microdroplet‐type, bulk‐like film, where viscoelastic IL patches decouple from the oscillating crystal. By correlating film morphology, surface composition, and QCM response, this study provides a comprehensive framework to interpret the limitations of QCM mass detection of IL films under vacuum.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CIQUP/Institute of Molecular Sciences (IMS), Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Porto, Portugal.
- International Iberian Nanotechnology Laboratory, Braga, Portugal.
- SPIN-Lab Centre for Microscopic Research on Matter, University of Silesia in Katowice, Chorzów, Poland.
- Institute of Chemistry, University of Silesia in Katowice, Katowice, Poland.
ORCID-Profile: José C S Costa
Zitieren
APA
Farinha, A. F. M., Silva, S. R. M. R., Alves, A. C. P. M., Santos, L. M. N. B. F., Bondarchuk, O., & Costa, J. C. S. (2026). Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology. ChemPhysChem, 27(7). https://doi.org/10.1002/cphc.70349
Vancouver
Farinha AFM, Silva SRMR, Alves ACPM, Santos LMNBF, Bondarchuk O, Costa JCS. Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology. ChemPhysChem. 2026;27(7). doi:10.1002/cphc.70349
BibTeX
@article{Farinha2026,
author = {Farinha, Artur F M and Silva, Soraia R M R and Alves, Alexandre C P M and Santos, Luís M N B F and Bondarchuk, Oleksandr and Costa, José C S},
title = {Quartz Crystal Microbalance Sensitivity Loss During Ionic Liquid Deposition: Insights into Film Structure and Morphology},
journal = {ChemPhysChem},
year = {2026},
volume = {27},
number = {7},
doi = {10.1002/cphc.70349}
}
EUVIMED