Incorporating Torsion Into 3D Geometric Reconstruction of Left‐Ventricle From 2D Echocardiography and Its Impact on Hemodynamics
International Journal for Numerical Methods in Biomedical Engineering · 2026
DOI: 10.1002/cnm.70220 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2026. Verfasst von Sai Sree Chandra Sirani und 5 weiteren Autor:innen. Beteiligte Einrichtung: J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, Texas, USA. Hauptthemen laut MEDLINE: Heart Ventricles, Hemodynamics, Echocardiography, Imaging, Three-Dimensional. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation.
Abstract (Originalsprache)
In addition to systolic contraction and diastolic relaxation, torsional motion is an essential component of left ventricle (LV) wall motion, but its effect on LV hemodynamics is not fully understood. To this end, the measured rotation of short‐axis sections is incorporated into our 3D reconstruction of LV from 2D echocardiography, which serves as input to the curvilinear immersed boundary framework for LV flow simulations. The geometry is validated against sonomicrometry measurements, whose difference is found to be within the typical myocardium thickness range, and the flow is validated against intracardiac flow velocity measured by Doppler ultrasound. To assess the impact of torsion, two simulations (one including torsion and one without in the reconstruction from the same set of images) are compared. It is found that including torsion in reconstruction for a normal LV does not change the geometry, and consequently the volume and flow rates, due to the circular shape of LV short‐axis sections. However, the time‐averaged wall shear force increases by 12.6% during systole and drops by 4.9% during diastole when torsion is included. Torsion also reduces washout efficiency for this subject, as the volume of fluid with residence time under one cycle is 16.6% lower, while fluid staying 1–2 cycles increases by 3.7%. Viscous frictional energy loss decreases by 3.8% for LV with torsion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, Texas, USA.
- Department of Cardiovascular Medicine, Mayo Clinic, Scottsdale, Arizona, USA.
ORCID-Profile: Sai Sree Chandra Sirani, Minako Katayama, Marek Belohlavek, Iman Borazjani
Förderung
- National Science Foundation
Zitieren
APA
Sirani, S. S. C., Geshani, H., Katayama, M., Abbas, S. S., Belohlavek, M., & Borazjani, I. (2026). Incorporating Torsion Into 3D Geometric Reconstruction of Left‐Ventricle From 2D Echocardiography and Its Impact on Hemodynamics. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70220
Vancouver
Sirani SSC, Geshani H, Katayama M, Abbas SS, Belohlavek M, Borazjani I. Incorporating Torsion Into 3D Geometric Reconstruction of Left‐Ventricle From 2D Echocardiography and Its Impact on Hemodynamics. International Journal for Numerical Methods in Biomedical Engineering. 2026. doi:10.1002/cnm.70220
BibTeX
@article{Sirani2026,
author = {Sirani, Sai Sree Chandra and Geshani, Hossein and Katayama, Minako and Abbas, Syed Samar and Belohlavek, Marek and Borazjani, Iman},
title = {Incorporating Torsion Into 3D Geometric Reconstruction of Left‐Ventricle From 2D Echocardiography and Its Impact on Hemodynamics},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2026},
doi = {10.1002/cnm.70220}
}
EUVIMED