Mechanics‐Oriented Coil Size Selection for an Internal Carotid Aneurysm With Fluid–Structure Interaction
International Journal for Numerical Methods in Biomedical Engineering · 2026
DOI: 10.1002/cnm.70139 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2026. Verfasst von Jiakun Han und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Sciences, Xi'an University of Science and Technology, Xi'an, China. Hauptthemen laut MEDLINE: Carotid Artery, Internal, Aneurysm, Intracranial Aneurysm. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shaanxi Province.
Abstract (Originalsprache)
The coil intervention is a common aneurysm treatment strategy, but the effect of coil size on aneurysm hemodynamics and mechanics is not fully understood. In this paper, how different sizes of coils affect the hemodynamic and mechanical properties of a real internal carotid artery (ICA) aneurysm was investigated. A fluid–structure interaction (FSI) method based on the Arbitrary Lagrangian–Eulerian (ALE) approach was used to consider non‐Newtonian blood flow, linear elastic arterial wall and simulations. It is indicated that with the increase of coil size, the hemodynamic parameters related to aneurysm such as wall shear stress (WSS), time‐averaged WSS (TAWSS) and oscillatory shear index (OSI) decreased significantly. However, too large coils will compress the parent artery, produce high TAWSS areas in adjacent branches, and cause stress concentration on the aneurysm wall. Moreover, both the average displacement and von Mises stress of the aneurysm dome initially decrease and then increase with coil size. The appropriate size of the coil is beneficial to minimize displacement and stress by reducing blood flow velocity and vortices. The effects of different coil sizes were predicted by computational fluid dynamics (CFD), and the individualized treatment plan was adjusted according to the aneurysm morphology and hemodynamic characteristics. Our results provide a new theoretical basis for interventional therapy and help to promote the transformation of coil intervention from empirical filling to mechanics‐oriented precision treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Sciences, Xi'an University of Science and Technology, Xi'an, China.
- Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China.
- The Second Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, China.
- School of Aeronautic Science and Engineering, Beihang University, Beijing, China.
ORCID-Profile: Jiakun Han
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shaanxi Province
Zitieren
APA
Han, J., Zhao, N., Li, W., & Zhao, S. (2026). Mechanics‐Oriented Coil Size Selection for an Internal Carotid Aneurysm With Fluid–Structure Interaction. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70139
Vancouver
Han J, Zhao N, Li W, Zhao S. Mechanics‐Oriented Coil Size Selection for an Internal Carotid Aneurysm With Fluid–Structure Interaction. International Journal for Numerical Methods in Biomedical Engineering. 2026. doi:10.1002/cnm.70139
BibTeX
@article{Han2026,
author = {Han, Jiakun and Zhao, Na and Li, Wei and Zhao, Shiwei},
title = {Mechanics‐Oriented Coil Size Selection for an Internal Carotid Aneurysm With Fluid–Structure Interaction},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2026},
doi = {10.1002/cnm.70139}
}
EUVIMED