Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms
International Journal for Numerical Methods in Biomedical Engineering · 2024
DOI: 10.1002/cnm.3880 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2024. Verfasst von Xiaoyu Ren und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Life Science, Beijing University of Technology, Beijing, China. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Embolization, Therapeutic, Hemodynamics. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China (Nos. 61931013, 82171886, 81701644, and 11832003), National Key Research and Development Program of China (2022YFC2704804).
Abstract (Originalsprache)
Endovascular coil embolization is the primary therapeutic modality for intracranial aneurysms. Substantial reports have been found regarding the coil packing density and inflow jet. However, the hemodynamic effect of increasing the rate of tamponade in the inflow jet area within the aneurysm remains unclear. In this study, individualized geometries of six intracranial aneurysms were recruited: all six aneurysms were located in the internal carotid artery. Two groups were created by changing the position and orientation of the microcatheter for the release of the third segment of the filling coil. The finite element method was used to simulate coil deployment. Computational fluid dynamics was used to characterize hemodynamics in post‐deployment aneurysms. The parameters evaluated included velocity reduction, wall shear stress (WSS), low WSS (LWSS), relative residence time (RRT), flow kinetic energy in the neck region of the aneurysms, and residual flow volume (RFV) in the aneurysms. At the peak time ( t = 0.17 s), the targeted deployment group has similar proportion of LWSS area to conventional deployment groups: targeted 78.13% ± 34.59% versus normal 74.20% ± 36.94% (mean ± SD, p = 0.583). The targeted deployment group has a higher RRT area (targeted 16.84% ± 5.58% vs. normal 6.42% ± 5.67% [mean ± SD, p = 0.009]), smaller flow kinetic energy (targeted 9.43 ± 4.33 vs. normal 16.23 ± 5.92 [mean ± SD, p = 0.047]), and a larger RFV in the aneurysms (targeted 35.97 ± 24.35 mm 3 vs. normal 25.80 ± 18.94 mm 3 [mean ± SD, p = 0.44]). Inflow jets play an important role in the treatment of aneurysms, and deploying filling coils in accordance with inflow jets may result in a better hemodynamic environment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing, China.
- Union Strong (Beijing) Technology co. Ltd., Beijing, China.
Förderung
- National Natural Science Foundation of China (Nos. 61931013, 82171886, 81701644, and 11832003)
- National Key Research and Development Program of China (2022YFC2704804)
Zitieren
APA
Ren, X., Gao, B., Lu, W., Yang, G., Wang, Y., & Yin, Y. (2024). Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.3880
Vancouver
Ren X, Gao B, Lu W, Yang G, Wang Y, Yin Y. Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms. International Journal for Numerical Methods in Biomedical Engineering. 2024. doi:10.1002/cnm.3880
BibTeX
@article{Ren2024,
author = {Ren, Xiaoyu and Gao, Bin and Lu, Wangsheng and Yang, Guangming and Wang, Yunjie and Yin, Yin},
title = {Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2024},
doi = {10.1002/cnm.3880}
}
EUVIMED