EUVIMEDEUVIMED entdecken
Vergleichsstudie

Bone Remodelling in Lumbar Spine: A Comparative Analysis of Ti‐Alloy, PEEK and CFR ‐ PEEK Implant Materials

Kishore Pradeep iD, Swapnil Mahadev Dhobale iD, Bidyut Pal iD

International Journal for Numerical Methods in Biomedical Engineering · 2025

DOI: 10.1002/cnm.70071 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Kishore Pradeep und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Howrah, West Bengal, India. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Polyethylene Glycols, Bone Remodeling, Ketones. Die Arbeit nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Long‐term performance‐based study to comprehend the biomechanics of Ti‐6Al‐4V, PEEK and CFR‐PEEK implant materials in fusing a lumbar spine is not available in literature. The present study investigates the performance of these implant materials in fusing an L4–L5 segment by executing a strain energy density‐based bone remodelling theory. The FE models of intact and implanted lumbar spines were reconstructed from computed tomography scan images and simulated for 500 N compressive load and a combination of 150 N preload and 10 Nm moment. The models attained equilibrium state when the apparent bone density change became less than 0.005 g cm −3 between two consecutive iterations. The implanted models' range of motion (ROM) has been reduced by 73%–85% for Ti‐6Al‐4V, 64%–78% for PEEK and 69%–81% for CFR‐PEEK implanted models. All models exhibit a substantial rise in bone density (30%) in the implant‐bone interface region and cancellous bone. However, the CFR‐PEEK implanted model exhibited a bone density loss of only 0%–0.3%, compared to the Ti‐6Al‐4V implanted model (0.3%–6.7%) and the PEEK model (1.5%–30%). The findings indicate that CFR‐PEEK material may be a better implant material than PEEK and Ti‐6Al‐4V while considering bone density distributions and equivalent strains from immediate post‐operative to equilibrium conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lumbar VertebraePolyethylene GlycolsBone RemodelingKetonesTitaniumAlloysProstheses and ImplantsBenzophenonesPolymersHumansFinite Element AnalysisBone DensityTomography, X-Ray Computed

Stichwörter der Autor:innen

adaptive bone remodellingcomputational simulationsfinite element analysisimplantation surgerieslumbar spine reconstruction

Substanzen

BenzophenonesPolymerspolyetheretherketonePolyethylene GlycolsKetonesTitaniumAlloystitanium alloy (TiAl6V4)

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Howrah, West Bengal, India.

ORCID-Profile: Kishore Pradeep, Swapnil Mahadev Dhobale, Bidyut Pal

Zitieren

APA

Pradeep, K., Dhobale, S. M., & Pal, B. (2025). Bone Remodelling in Lumbar Spine: A Comparative Analysis of Ti‐Alloy, PEEK and CFR ‐ PEEK Implant Materials. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70071

Vancouver

Pradeep K, Dhobale SM, Pal B. Bone Remodelling in Lumbar Spine: A Comparative Analysis of Ti‐Alloy, PEEK and CFR ‐ PEEK Implant Materials. International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.70071

BibTeX
@article{Pradeep2025,
  author = {Pradeep, Kishore and Dhobale, Swapnil Mahadev and Pal, Bidyut},
  title = {Bone Remodelling in Lumbar Spine: A Comparative Analysis of Ti‐Alloy, PEEK and CFR ‐ PEEK Implant Materials},
  journal = {International Journal for Numerical Methods in Biomedical Engineering},
  year = {2025},
  doi = {10.1002/cnm.70071}
}
Kostenlos starten →