Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation
International Journal for Numerical Methods in Biomedical Engineering · 2023
DOI: 10.1002/cnm.3705 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2023. Verfasst von Qingxin Xue und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Heart-Assist Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Extracorporeal membrane oxygenation (ECMO) is a life support system used in the treatment of severe respiratory and circulatory failure. High shear stress caused by the high rotational speed of centrifugal blood pumps can cause hemolysis and platelet activation, which are among the major factors leading to the complications of the ECMO system. In this study, a novel blood pump named rotary displacement blood pump (RDBP), which can considerably reduce rotational speed and shear stress while ensuring the normal pressure flow relationship, was proposed. We employed computational fluid dynamics (CFD) analysis to investigate the performance of RDBP under adult ECMO support operating conditions (5 L/min with 350 mmHg). The efficiency and H‐Q curves of the RDBP were calculated to evaluate its hydraulic performance, and pressure, flow patterns, and shear stress distribution were analyzed to estimate the hemodynamic characteristics in the pump. In addition, the modified index of hemolysis (MIH) was calculated for the RDBP based on a Eulerian approach. The hydraulic efficiency of the RDBP was 47.28%. The velocity distribution of flow field in the pump was relatively uniform. Most of the liquid (more than 75%) in the pump was exposed to low scale shear stress (9 Pa) volume fraction of the RDBP was small and located in the boundary areas between the rotor's edge and the housing. The MIH value of the RDBP was 9.87 ± 0.93 (mean ± SD). The RDBP can achieve better hydraulic efficiency and hemodynamic performance at lower rotational speed. The design of this novel pump is expected to provide a new direction for developing a blood pump for ECMO.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China.
- National Institutes for Food and Drug Control, Institute for Medical Device Control, Beijing, China.
- Department of Cardiac Surgery, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
- National Clinical Research Center for Child Health, The Children's Hospital Zhejiang University School of Medicine, Hangzhou, China.
ORCID-Profile: Bin Gao
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Xue, Q., Ren, X., Gao, B., Li, S., Song, Z., Ding, J., & Chang, Y. (2023). Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.3705
Vancouver
Xue Q, Ren X, Gao B, Li S, Song Z, Ding J, et al. Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation. International Journal for Numerical Methods in Biomedical Engineering. 2023. doi:10.1002/cnm.3705
BibTeX
@article{Xue2023,
author = {Xue, Qingxin and Ren, Xiaoyu and Gao, Bin and Li, Shu and Song, Zhiming and Ding, Jinli and Chang, Yu},
title = {Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2023},
doi = {10.1002/cnm.3705}
}