EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Initial Stages of Gas Diffusion Electrode Flow‐Cell CO 2 Electrolysis—Monitoring via Synergetic Online Mass Spectrometry and Rapid Sample‐Trapping Gas Chromatography

Christina Martens, Bernhard Schmid, Albert Luft, Nevfel Sarioglu, Hermann Tempel, Rüdiger‐A. Eichel

Chemistry–Methods · 2025-08 · 5 (8)

DOI: 10.1002/cmtd.202400092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemistry–Methods, online erschienen am 27.04.2025. Verfasst von Christina Martens und 5 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High‐performance gas diffusion electrodes (GDEs) are crucial for large‐scale CO 2 ‐electrolysis. During initial electrode polarization, the startup procedure plays a critical role in determining the subsequent performance of electrodes. This phase influences the course and rate of catalyst formation, as well as electrode‐wetting, and must be carefully managed to prevent initial electrode damage. Maintaining ideal conditions despite added constraints and complexity during scale‐up requires in‐depth understanding of these operational phases. However, progress is limited by the current inability to rapidly analyze product gases. To address this, we present a modified gas chromatography (GC) method capable of sampling every 30 seconds within a limited timeframe, maintaining full data quality. This method was compared and combined with online mass spectrometry (MS), which is faster but comes with calibration challenges and spectral overlaps. We explore the strengths, limitations, and potential synergies of both techniques during electrolyzer startup and for current steps on GDEs with different catalyst layer designs. Experimental results reveal that concentration gradients and additional electrode‐wetting under load primarily occur within the first two minutes. Both fast‐GC and MS methods are effective for product gas analysis within this critical timeframe. We demonstrate the calibration of MS fragmentation signal corrections using simultaneous GC data.

Förderung

  • Federal Ministry of Education and Research

Zitieren

APA

Martens, C., Schmid, B., Luft, A., Sarioglu, N., Tempel, H., & Eichel, R. (2025). Initial Stages of Gas Diffusion Electrode Flow‐Cell CO 2 Electrolysis—Monitoring via Synergetic Online Mass Spectrometry and Rapid Sample‐Trapping Gas Chromatography. Chemistry–Methods, 5(8). https://doi.org/10.1002/cmtd.202400092

Vancouver

Martens C, Schmid B, Luft A, Sarioglu N, Tempel H, Eichel R. Initial Stages of Gas Diffusion Electrode Flow‐Cell CO 2 Electrolysis—Monitoring via Synergetic Online Mass Spectrometry and Rapid Sample‐Trapping Gas Chromatography. Chemistry–Methods. 2025;5(8). doi:10.1002/cmtd.202400092

BibTeX
@article{Martens2025,
  author = {Martens, Christina and Schmid, Bernhard and Luft, Albert and Sarioglu, Nevfel and Tempel, Hermann and Eichel, Rüdiger‐A.},
  title = {Initial Stages of Gas Diffusion Electrode Flow‐Cell CO 2 Electrolysis—Monitoring via Synergetic Online Mass Spectrometry and Rapid Sample‐Trapping Gas Chromatography},
  journal = {Chemistry–Methods},
  year = {2025},
  volume = {5},
  number = {8},
  doi = {10.1002/cmtd.202400092}
}
Kostenlos starten →