EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Safety and Efficacy of Pulsed‐Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta‐Analysis

Yi Cai, Hao Chen, Miao‐Fu Li, Yi‐Zhou Xu

Clinical Cardiology · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

ABSTRACT Background Pulsed‐field ablation (PFA) is an emerging technology for atrial fibrillation (AF) ablation. However, there is few studies comparing the clinical advantages and disadvantages of PFA and cryoballoon ablation (CBA). This study aimed to perform a comprehensive meta‐analysis to evaluate the efficacy and safety of PFA using a pentaspline ablation catheter compared with CBA for treating AF. Methods This study was registered in the International Prospective Register of Systematic Reviews (ID: CRD420251061599). Studies comparing PFA using a pentaspline ablation catheter with CBA for pulmonary vein isolation (PVI) were systematically searched from database inception to March 2025. Results Six trials involving 2024 patients were included. No significant difference was observed in atrial tachyarrhythmia recurrence between PFA and CBA (OR) = 0.71; 95% confidence interval (CI): 0.48 to 1.06). However, in patients with paroxysmal AF, the PFA group exhibited a lower incidence of AT recurrence (OR = 0.62; 95% CI: 0.46 to 0.85). PFA was superior to CBA in terms of ablation time (MD) = −14.12; 95% CI: −16.31 to −11.93) and left atrial dwell time (MD = −9.44; 95% CI: −15.69 to −3.19). Hypersensitive troponin release was higher in the PFA group (MD = 547.29; 95% CI: 53.55 to 1041.03), while CBA was associated with a higher incidence of phrenic nerve palsy (OR = 0.06; 95% CI: 0.01 to 0.30). Conclusion PFA demonstrates superior safety and efficacy compared with CBA for PVI in patients with AF. These findings provide additional procedural options for patients and electrophysiologists in clinical practice.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Yi Cai, Hao Chen, Miao‐Fu Li, Yi‐Zhou Xu
Quelle
Clinical Cardiology
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0160-9289, 1932-8737
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Yi Cai, Hao Chen, Miao‐Fu Li, Yi‐Zhou Xu (2026). Safety and Efficacy of Pulsed‐Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta‐Analysis. Clinical Cardiology. https://doi.org/10.1002/clc.70459
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1 · Lizenz 2