Characterization of temporal electrical activity patterns for detection of critical isthmus regions of recurrent atypical atrial flutter
Clinical Cardiology · 2023
DOI: 10.1002/clc.24009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Cardiology, 2023. Verfasst von Nadine Vonderlin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Vascular Medicine, West-German Heart and Vascular Center Essen, University of Essen Medical School, University Duisburg-…. Hauptthemen laut MEDLINE: Atrial Flutter, Tachycardia, Supraventricular, Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Identifying the critical isthmus region (CIR) of atrial re‐entry tachycardias (AT) is challenging. The Lumipoint® (LP) software, developed for the Rhythmia® mapping system, aims to facilitate the successful ablation of ATs by identifying the CIR.
Objective
The objective of this study was to evaluate the quality of LP regarding the percentage of arrhythmia‐relevant CIR in patients with atypical atrial flutter (AAF).
Methods
In this retrospective study, we analyzed 57 AAF forms. Electrical activity (EA) was mapped over tachycardia cycle length resulting in a two‐dimensional EA pattern. The hypothesis was that EA minima suggest potential CIRs with slow‐conduction‐zone.
Results
A total of n = 33 patients were included, with the majority of patients being already preablated (69.7%). LP algorithm identified a mean of 2.4 EA minima and 4.4 suggested CIRs per AAF form. Overall, we observed a low probability of identifying only the relevant CIR (POR) at 12.3% but a high probability that at least one CIR is detected (PALO) at 98.2%. Detailed analysis revealed EA minima depth (≤20%) and width (>50 ms) as the best predictors of relevant CIRs. Wide minima occurred rarely (17.5%), while low minima were more frequently present (75.4%). Minima depth of EA ≤ 20% showed the best PALO/POR overall (95% and 60%, respectively). Analysis in recurrent AAF ablations (five patients) revealed that CIR in de novo AAF was already detected by LP during the index procedure.
Conclusion
The LP algorithm provides an excellent PALO (98.2%), but poor POR (12.3%) to detect the CIR in AAF. POR improved by preselection of the lowest and widest EA minima. In addition, there might be the role of initial bystander CIRs becoming relevant for future AAFs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology and Vascular Medicine, West-German Heart and Vascular Center Essen, University of Essen Medical School, University Duisburg-Essen, Essen, Germany.
- German Centre for Cardiovascular Research (DZHK), Berlin, Germany.
- Institute of Pharmacology, West German Heart and Vascular Center, University Duisburg-Essen, Essen, Germany.
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, USA.
- Department of Medicine and Research Center, Montreal Heart Institute, Université de Montréal, Montréal, Quebec, Canada.
- Department of Cardiology and Vascular Medicine, University Hospital Frankfurt, Goethe University, Frankfurt, Germany.
Zitieren
APA
Vonderlin, N., Siebermair, J., Mahabadi, A., Pesch, E., Koehler, M., Dobrev, D., Janosi, R. A., Rassaf, T., & Wakili, R. (2023). Characterization of temporal electrical activity patterns for detection of critical isthmus regions of recurrent atypical atrial flutter. Clinical Cardiology. https://doi.org/10.1002/clc.24009
Vancouver
Vonderlin N, Siebermair J, Mahabadi A, Pesch E, Koehler M, Dobrev D, et al. Characterization of temporal electrical activity patterns for detection of critical isthmus regions of recurrent atypical atrial flutter. Clinical Cardiology. 2023. doi:10.1002/clc.24009
BibTeX
@article{Vonderlin2023,
author = {Vonderlin, Nadine and Siebermair, Johannes and Mahabadi, Amir and Pesch, Elena and Koehler, Miriam and Dobrev, Dobromir and Janosi, Rolf Alexander and Rassaf, Tienush and Wakili, Reza},
title = {Characterization of temporal electrical activity patterns for detection of critical isthmus regions of recurrent atypical atrial flutter},
journal = {Clinical Cardiology},
year = {2023},
doi = {10.1002/clc.24009}
}
EUVIMED