Comparison of Tests and Design Methods for Eccentrically Connected Gusset Plates in Compression
ce/papers · 2026-09 · 9 (2-3) · 1603-1608
DOI: 10.1002/cepa.70392 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Pavel Bartůšek und 4 weiteren Autor:innen. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
An experimental study of twelve bolted single‐brace eccentric gusset plate connections in compression was carried out. Ten of the tested gusset plate specimens were made of steel S355 and two of steel S690. The specimens varied also in their geometry, namely the connection plate length, plate tapering, plate thickness, weld along one or two sides of the plate, and the slenderness of the connected CHS member itself. In addition, tensile tests were performed to determine the actual material properties of the individual components. The results obtained from the full‐scale experimental tests were compared with predictions from existing analytical models. The measured load‐bearing capacities demonstrated the influence of plate slenderness on the compressive resistance of the connection.
Zitieren
APA
Bartůšek, P., Jandera, M., Cábová, K., Feber, N., & Kuříková, M. (2026). Comparison of Tests and Design Methods for Eccentrically Connected Gusset Plates in Compression. ce/papers, 9(2-3), 1603-1608. https://doi.org/10.1002/cepa.70392
Vancouver
Bartůšek P, Jandera M, Cábová K, Feber N, Kuříková M. Comparison of Tests and Design Methods for Eccentrically Connected Gusset Plates in Compression. ce/papers. 2026;9(2-3):1603-1608. doi:10.1002/cepa.70392
BibTeX
@article{Bartek2026,
author = {Bartůšek, Pavel and Jandera, Michal and Cábová, Kamila and Feber, Nina and Kuříková, Marta},
title = {Comparison of Tests and Design Methods for Eccentrically Connected Gusset Plates in Compression},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {1603--1608},
doi = {10.1002/cepa.70392}
}